Reinforcing the pulmonary artery autograft in the aortic position with a textile mesh: a histological evaluation

Abstract: Reinforcing an interposition pulmonary autograft in the descending aorta with a macroporous mesh showed promising results in limiting autograft dilatation in this sheep model. Histological evaluation revealed atrophy of the smooth muscle cell and consequently thinning of the vessel wall within the mesh support.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
15
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 21 publications
(18 citation statements)
references
References 27 publications
2
15
0
1
Order By: Relevance
“…7). These results are in line with our previous studies [27][28][29][30] . In contrast, a patient study examining the capacity of the macroporous material to withstand further dilatation of a weakened vessel wall does not mention atrophy of the SMC 31 .…”
Section: Effect Of Systemic Conditions On Autograft Dilatationsupporting
confidence: 94%
See 1 more Smart Citation
“…7). These results are in line with our previous studies [27][28][29][30] . In contrast, a patient study examining the capacity of the macroporous material to withstand further dilatation of a weakened vessel wall does not mention atrophy of the SMC 31 .…”
Section: Effect Of Systemic Conditions On Autograft Dilatationsupporting
confidence: 94%
“…Overall the meshes seemed well incorporated in all sheep, again in line with our previous studies [27][28][29][30] . Nevertheless, since the mesh material was not personalized for each surgery, some areas presented gaps between the mesh and the native wall which were filled with edema or proliferating, but inactive SMC.…”
Section: Effect Of Systemic Conditions On Autograft Dilatationsupporting
confidence: 89%
“…When studying the experiments reported in [31], histology on the remodelled autograft showed an inhomogeneous pattern across the circumference of the vessel. Some zones showed evident thickening with new matrix deposition, whereas other zones had no thickening at all.…”
Section: Significance Of the Resultsmentioning
confidence: 99%
“…As a test case for the algorithm described in the previous section, we use the results obtained by [10] and [31]. In this experimental study, a section of the pulmonary autograft was placed in the descending aorta in two sheep.…”
Section: Experimental Protocolmentioning
confidence: 99%
See 1 more Smart Citation