2007
DOI: 10.1016/j.bios.2006.03.010
|View full text |Cite
|
Sign up to set email alerts
|

Registration of T-2 mycotoxin with total internal reflection ellipsometry and QCM impedance methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

8
78
1
1

Year Published

2009
2009
2021
2021

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 68 publications
(88 citation statements)
references
References 9 publications
8
78
1
1
Order By: Relevance
“…Recently developed method of total internal reflection ellipsometry (TIRE) proved to be very much suitable for immunosensing and particularly attractive for detection of low molecular weight toxins [11][12][13][14].…”
Section: Introductionmentioning
confidence: 99%
“…Recently developed method of total internal reflection ellipsometry (TIRE) proved to be very much suitable for immunosensing and particularly attractive for detection of low molecular weight toxins [11][12][13][14].…”
Section: Introductionmentioning
confidence: 99%
“…It is worth noting that the concentration of urea in the blood serum of healthy individuals is 2.50 -8.33 mM and it increases to 50 -83 mM in the case of kidney failure as a result of various diseases. So enzymatic biosensor based on the proposed biological membranes can be successfully used for measuring the concentration of urea in the blood without its additional dilution that distinguishes this biosensor from others early proposed (Arenkov et al, 1994a;1994b;Levkovets et al, 2004;Nabok et al, 2007;Starodub et al, 1999a;2000a;Starodub, 2006;Starodub et al, 2008). Dependence of biosensor response on temperature (Fig.…”
Section: Characterization Of Work Efficiency Of Urea Biosensor With Lmentioning
confidence: 92%
“…Early (Arenkov et al, 1994a;1994b;Levkovets et al, 2004;Nabok et al, 2007;Starodub et al, 1999a;2000a;Starodub, 2006;Starodub et al, 2008) we have developed prototypes of the enzyme-and immune biosensors based on the IsFETs and the electrolyte insulator semiconductors (EIS) structures. Both types of the biosensors are perspective for use in different fields, in particular, medicine, biotechnology and environmental monitoring.…”
Section: Application Of Photo Polymerisable Matrix At the Creation Ofmentioning
confidence: 99%
“…6). It is necessary to underline that immune biosensor based on total reflection ellipsometry has much more sensitivity but it is more complicate in respect to analysis fulfillment [9]. The described immune biosensor based on the nanostructured silicon provides very simple and faster analysis (about 10 min if photoresistor with the appropriate Ab will be preliminary prepared).…”
Section: Discussionmentioning
confidence: 99%