2011
DOI: 10.1007/s12668-011-0006-5
|View full text |Cite
|
Sign up to set email alerts
|

Detection of Aflatoxin B1 with a Label-Free Ellipsometry Immunosensor

Abstract: The method of spectroscopic ellipsometry in total internal reflection mode (TIRE) was utilised for detection of Aflatoxin B1. The method of TIRE with the improved data analysis was capable of detection of aflatoxin molecules in low concentrations (down to 0.04 ng/ml) using a label-free and cost-effective direct immunoassay format. TIRE study of the binding kinetics yielded a large value of the association constant in the range of 10 6 l mol −1 which is typical for highly specific immune reactions. The comparis… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
21
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(23 citation statements)
references
References 20 publications
2
21
0
Order By: Relevance
“…Test experiments were carried out using the TIRE method in order to find out the concentration of ZON in the solution after the treatment. In these measurements the antibodies to ZON were electrostatically immobilized on the surface of gold via the layers of P AH and protein A following well established experimental routine described in detail earlier [7][8][9][10]. A clear solution containing the residues of ZON was collected with a micropipette after sedimentation of microparticles was injected into the measurement cell and TIRE spectra were recorded.…”
Section: Discussion 3 Results and Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Test experiments were carried out using the TIRE method in order to find out the concentration of ZON in the solution after the treatment. In these measurements the antibodies to ZON were electrostatically immobilized on the surface of gold via the layers of P AH and protein A following well established experimental routine described in detail earlier [7][8][9][10]. A clear solution containing the residues of ZON was collected with a micropipette after sedimentation of microparticles was injected into the measurement cell and TIRE spectra were recorded.…”
Section: Discussion 3 Results and Discussionmentioning
confidence: 99%
“…Detection of mycotoxins, a challenging task due to low molecular weight of these molecules, was addressed in our previous publications; the method of total reflection 978-1-4577 -0624-0/11/$26.00 ©2011 IEEE ellipsometry (TIRE) was successfully utilised for detection of T2 mycotoxin [7,8], zearalenone [9] and aflatoxin B1 [10]. The sensitivity of TIRE measurements was high enough to allow label-free detection of the above toxins in low concentrations (down to 0.1 ng/ml) in a cost-effective direct immunoassay with respective specific antibodies.…”
Section: Discussion 1 Problem Outlinementioning
confidence: 99%
See 3 more Smart Citations