2010
DOI: 10.3928/1081597x-20100408-01
|View full text |Cite
|
Sign up to set email alerts
|

Refractive Surgical Correction of Presbyopia with the AcuFocus Small Aperture Corneal Inlay: Two-Year Follow-Up

Abstract: The ACI 7000 seems to provide a safe and effective treatment for presbyopia over follow-up of 2 years.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

7
92
6
10

Year Published

2011
2011
2019
2019

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 112 publications
(115 citation statements)
references
References 26 publications
7
92
6
10
Order By: Relevance
“…A brief summary and comparison of the clinical studies with different methods to treat presbyopia is presented in Table 1, although intermediate visual acuity is not included due to the unavailability of this metric in most studies. However, Seyeddain et al 26 reported in their cohort, 71.9% treatments achieving 20/20 or better UIVA compared to the 63% reported in our cohort. Methods depending only on the depth of focus might face difficulty to create more than 1.5D of near vision independence.…”
Section: Retreatmentscontrasting
confidence: 44%
“…A brief summary and comparison of the clinical studies with different methods to treat presbyopia is presented in Table 1, although intermediate visual acuity is not included due to the unavailability of this metric in most studies. However, Seyeddain et al 26 reported in their cohort, 71.9% treatments achieving 20/20 or better UIVA compared to the 63% reported in our cohort. Methods depending only on the depth of focus might face difficulty to create more than 1.5D of near vision independence.…”
Section: Retreatmentscontrasting
confidence: 44%
“…Without the need of a real implantation, the instrument realistically simulates different aspects of monocular and binocular visual conditions with the small aperture approach. When comparing visual performance with the simulated small aperture with clinical results [4,6], both monocular and binocular distance VA are in good agreement. However, near VAs are lower in this study by about 1-2 lines.…”
Section: Discussionmentioning
confidence: 60%
“…The efficacy of small aperture monovision [4,5,21,22,26] and traditional monovision [20,[27][28][29] has been investigated in several studies. However, no direct comparison has been performed so far.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…It is an opaque material measuring 3.8 mm diameter and 1.6 mm diameter of opening at the center with 8,400 microperforation to allow flow of nutrients and metabolites in cornea layers. It works based on the depth of focus principle (pinhole effect) (Seyeddain et al 2010). The inlay is implanted by a refractive surgeon on the cornea stromal layer by creating a corneal flap using a femtosecond laser.…”
Section: Introductionmentioning
confidence: 99%