A fundamental problem facing sensory systems is to recover useful information about the external world from signals that are corrupted by the sensory process itself. Retinal images in the human eye are affected by optical aberrations that cannot be corrected with ordinary spectacles or contact lenses, and the specific pattern of these aberrations is different in every eye. Though these aberrations always blur the retinal image, our subjective impression is that the visual world is sharp and clear, suggesting that the brain might compensate for their subjective influence. The recent introduction of adaptive optics to control the eye's aberrations now makes it possible to directly test this idea. If the brain compensates for the eye's aberrations, vision should be clearest with the eye's own aberrations rather than with unfamiliar ones. We asked subjects to view a stimulus through an adaptive optics system that either recreated their own aberrations or a rotated version of them. For all five subjects tested, the stimulus seen with the subject's own aberrations was always sharper than when seen through the rotated version. This supports the hypothesis that the neural visual system is adapted to the eye's aberrations, thereby removing somehow the effects of blur generated by the sensory apparatus from visual experience. This result could have important implications for methods to correct higher order aberrations with customized refractive surgery because some benefits of optimizing the correction optically might be undone by the nervous system's compensation for the old aberrations.
It is often difficult to find consistent changes in the retinal microvasculature due to large intersubject variability. However, with a novel application of AOSLO imaging, it is possible to visualize parafoveal capillaries and identify AV channels noninvasively. AV channels are disrupted in type 2 diabetes, even before the onset of diabetic retinopathy.
Correcting ocular spherical aberration improves spatial vision in the best-focus position without compromising the subjective tolerance to defocus.
Adaptive optics for the human eye has two main applications: to obtain high-resolution images of the retina and to produce aberration-free retinal images to improve vision. Additionally, it can be used to modify the aberrations of the eye to perform experiments to study the visual function. We have developed an adaptive optics prototype by using a liquid crystal spatial light modulator (Hamamatsu Programmable Phase Modulator X8267). The performance of this device both as aberration generator and corrector has been evaluated. The system operated either with red (633nm) or infrared (780nm) illumination and used a real-time Hartmann-Shack wave-front sensor (25 Hz). The aberration generation capabilities of the modulator were checked by inducing different amounts of single Zernike terms. For a wide range of values, the aberration production process was found to be linear, with negligible cross-coupling between Zernike terms. Subsequently, the modulator was demonstrated to be able to correct the aberrations of an artificial eye in a single step. And finally, it was successfully operated in close-loop mode for aberration correction in living human eyes. Despite its slow temporal response, when compared to currently available deformable mirrors, this device presents advantages in terms of effective stroke and mode independence. Accordingly, the programmable phase modulator allows production and compensation of a wide range of aberrations, surpassing in this respect the performance of low-cost mirrors and standing comparison against more expensive devices.
An instrument permitting visual testing in white light following the correction of spherical aberration (SA) and longitudinal chromatic aberration (LCA) was used to explore the visual effect of the combined correction of SA and LCA in future new intraocular lenses (IOLs). The LCA of the eye was corrected using a diffractive element and SA was controlled by an adaptive optics instrument. A visual channel in the system allows for the measurement of visual acuity (VA) and contrast sensitivity (CS) at 6 c/deg in three subjects, for the four different conditions resulting from the combination of the presence or absence of LCA and SA. In the cases where SA is present, the average SA value found in pseudophakic patients is induced. Improvements in VA were found when SA alone or combined with LCA were corrected. For CS, only the combined correction of SA and LCA provided a significant improvement over the uncorrected case. The visual improvement provided by the correction of SA was higher than that from correcting LCA, while the combined correction of LCA and SA provided the best visual performance. This suggests that an aspheric achromatic IOL may provide some visual benefit when compared to standard IOLs.
The adaptive optics vision simulator reduced the root-mean-square wavefront aberration of the eye by up to a factor of 4 and allowed noninvasive testing of the visual performance resulting from any ocular wavefront aberration introduced by customized correction procedures. This study showed that, on average, contrast performance peaked when SA was completely corrected.
No abstract
Retinal sampling poses a fundamental limit to resolution acuity in the periphery. However, reduced image quality from optical aberrations may also influence peripheral resolution. In this study, we investigate the impact of different degrees of optical correction on acuity in the periphery. We used an adaptive optics system to measure and modify the off-axis aberrations of the right eye of six normal subjects at 20 degrees eccentricity. The system consists of a Hartmann-Shack sensor, a deformable mirror, and a channel for visual testing. Four different optical corrections were tested, ranging from foveal sphero-cylindrical correction to full correction of eccentric low- and high-order monochromatic aberrations. High-contrast visual acuity was measured in green light using a forced choice procedure with Landolt C's, viewed via the deformable mirror through a 4.8-mm artificial pupil. The Zernike terms mainly induced by eccentricity were defocus and with- and against-the-rule astigmatism and each correction condition was successfully implemented. On average, resolution decimal visual acuity improved from 0.057 to 0.061 as the total root-mean-square wavefront error changed from 1.01 mum to 0.05 mum. However, this small tendency of improvement in visual acuity with correction was not significant. The results suggest that for our experimental conditions and subjects, the resolution acuity in the periphery cannot be improved with optical correction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.