1991
DOI: 10.1016/0002-9149(91)90558-3
|View full text |Cite
|
Sign up to set email alerts
|

Reference values and reproducibility of Doppler echocardiography in the assessment of the tricuspid valve and right ventricular diastolic function in normal subjects

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

7
21
0
13

Year Published

1995
1995
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 63 publications
(41 citation statements)
references
References 15 publications
7
21
0
13
Order By: Relevance
“…In normal subjects, the age dependency of the tricuspid peak E velocity, E/A ratios and atrial filling fraction has been previously described in some reports [1, 2, 3, 4]but not in others [5, 6]. This study has shown that this age dependency is also present in subjects with a variety of RV pathologic findings.…”
Section: Discussionsupporting
confidence: 69%
See 2 more Smart Citations
“…In normal subjects, the age dependency of the tricuspid peak E velocity, E/A ratios and atrial filling fraction has been previously described in some reports [1, 2, 3, 4]but not in others [5, 6]. This study has shown that this age dependency is also present in subjects with a variety of RV pathologic findings.…”
Section: Discussionsupporting
confidence: 69%
“…This study failed to demonstrate any effect of TR on peak A, D and atrial reversal velocity or E wave deceleration time. Prior reports on the evaluation of RV diastolic function have excluded patients with significant TR [5, 6, 9, 10, 11, 12]. Excluding patients with TR seems impractical as many of the patients in whom assessment of RV diastolic function would be relevant commonly have some degree of TR (i.e.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…141 Com esta técnica, a medida das velocidades transtricuspídeas pode ser conseguida na maior parte dos pacientes, com uma baixa variabilidade inter e intraobservador. 146 O traçado obtido deve ter pelo menos 5 batimentos consecutivos em pausa expiratória. 147 .…”
Section: B Medidas Para Avaliação Da Disfunção Diastólicaunclassified
“…103 Tricuspid inflow measures can be achieved with high reproducibility. 104 The presence of moderate to severe TR can confound measurements of the tricuspid inflow velocities and are excluded from most studies. In PH patients with advanced disease and evident RVmediated impairment of LV filling, the late-diastolic LV filling pat- tern through the mitral valve will reverse, leading to E < A, and a short E deceleration time has been observed in adults.…”
Section: Rv and LV Diastolic Functionmentioning
confidence: 99%