Reduction of the pace polarization artefact for capture detection applications by a tri-phasic stimulation pulse

Abstract: This study investigated the ability to minimize pace polarization artefacts (PPA) by adjusting the post-stimulus pulse duration of a tri-phasic stimulation pulse. Adjustment of the stimulation pulse was enabled by downloading special study software into an already implanted pacemaker. Tests were performed in a total of 296 atrial leads and 311 ventricular leads. Both chronic and acute leads were included in the study. Statistically significant differences were found in the initial PPA (without any adjustment o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(1 citation statement)
references
References 3 publications
0
1
0
Order By: Relevance
“…The ability to reduce or eliminate the pacing‐induced afterpotential or ART that occurs simultaneously with the AER would significantly improve the ability of the pacemaker to determine atrial capture. Several technologies have been tested to reduce the ART including reduction of polarization voltage by electrode coatings (TiN, platinum black, and iridium oxide), 5,6 use of various triphasic stimulation waveforms, 11,12 and reduction of coupling capacitance 7 . Unfortunately, all of these methods have proven to have their own unsatisfactory limitations including the potential to increase demand on pulse generator battery as this is associated with triphasic stimulation.…”
Section: Discussionmentioning
confidence: 99%
“…The ability to reduce or eliminate the pacing‐induced afterpotential or ART that occurs simultaneously with the AER would significantly improve the ability of the pacemaker to determine atrial capture. Several technologies have been tested to reduce the ART including reduction of polarization voltage by electrode coatings (TiN, platinum black, and iridium oxide), 5,6 use of various triphasic stimulation waveforms, 11,12 and reduction of coupling capacitance 7 . Unfortunately, all of these methods have proven to have their own unsatisfactory limitations including the potential to increase demand on pulse generator battery as this is associated with triphasic stimulation.…”
Section: Discussionmentioning
confidence: 99%