2010
DOI: 10.1002/jms.1793
|View full text |Cite
|
Sign up to set email alerts
|

Reduction from copper(II) to copper(I) upon collisional activation of (pyridine)2CuCl+

Abstract: Electrospray ionization of dilute aqueous solutions of copper(II) chloride-containing traces of pyridine (py) as well as ammonia permits the generation of the gaseous ions (py)(2) Cu(+) and (py)(2) CuCl(+) , of which the latter is a formal copper(II) compound, whereas the former contains copper(I). Collision-induced dissociation of the mass-selected ions in an ion-trap mass spectrometer (IT-MS) leads to a loss of pyridine from (py)(2) Cu(+) , whereas an expulsion of atomic chlorine largely prevails for (py)(2)… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
24
0

Year Published

2011
2011
2014
2014

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 52 publications
(25 citation statements)
references
References 72 publications
1
24
0
Order By: Relevance
“…A method has been proposed [33,34] and used [35][36][37] to estimate the enthalpies of fragmentations from these curves. To this end, it was suggested to consider the phenomenological appearance energy AEs (AEexp), i.e.…”
Section: Resultsmentioning
confidence: 99%
“…A method has been proposed [33,34] and used [35][36][37] to estimate the enthalpies of fragmentations from these curves. To this end, it was suggested to consider the phenomenological appearance energy AEs (AEexp), i.e.…”
Section: Resultsmentioning
confidence: 99%
“…The collision‐induced dissociation (CID)‐MS experiments were performed by application of an excitation AC voltage to the end caps of the ion trap to induce collisions of the isolated ions (isolation width at 1.2 u) for a period of 30 ms and variable excitation amplitudes. Note that the software of the Finnigan ion trap applies a ‘normalized collision energy’ (see Finnigan Product Support Bulletin 104) by which the mass of the target ion is automatically considered in the calculation of the excitation amplitude in the CID experiments . Data acquisition and analysis were performed using the Xcalibur software package (version 2.0 SR1).…”
Section: Methodsmentioning
confidence: 99%
“…The abundances of the various palladium-containing clusters given in the diagrams below refer to the integrated isotope envelopes after correction for the baseline as well as signals of the pure solvent. Low-energy CID was performed by application of an excitation AC voltage to the end caps of the ion trap to induce collisions of the mass-selected ions with the helium buffer gas for a period of 20 ms at a trapping parameter of q z = 0.25 [35][36][37]. For all mass spectra 200 scans were averaged with the XCalibur software.…”
Section: Methodsmentioning
confidence: 99%
“…The large amount of clustering in both positive and negative ion mode together with the low total ion currents compared to other metal(II) salts [20,23,25,26,28,31,32,36] or palladium complexes with larger ligands [27,44,45] suggests a significant amount of aggregation of PdCl 2 in acetonitrile solution. Provided these aggregates were comprising larger numbers of palladium atoms, the ESI mass spectra would always sample only the fractional amount of smaller clusters, either present in solution or formed in the ESI process itself, despite the fact that we applied relatively soft ionization conditions.…”
Section: Concentration Dependencesmentioning
confidence: 97%