Recursive Digital Filter Based Control for Power Quality Improvement of Grid Tied Solar PV System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 28 publications
0
5
0
Order By: Relevance
“…Various modern/traditional control techniques for similar SPVS, including SOGI-FLL, SRFT-PLL, and recursive digital filters, have been developed to address the issue of harmonics alleviation in supply current when dealing with distorted grid scenarios. These techniques have demonstrated a supply current's THD of approximately 4%, 4.3%, and 3.4%, respectively, as reported in the existing literature [26]. Through the application of traditional normalized LMS and dq0 techniques for SPVS, it has been shown that the grid current exhibits THD levels of 4.21% and 3.32%, respectively [27].…”
Section: Response At Constant š‘ƒmentioning
confidence: 56%
“…Various modern/traditional control techniques for similar SPVS, including SOGI-FLL, SRFT-PLL, and recursive digital filters, have been developed to address the issue of harmonics alleviation in supply current when dealing with distorted grid scenarios. These techniques have demonstrated a supply current's THD of approximately 4%, 4.3%, and 3.4%, respectively, as reported in the existing literature [26]. Through the application of traditional normalized LMS and dq0 techniques for SPVS, it has been shown that the grid current exhibits THD levels of 4.21% and 3.32%, respectively [27].…”
Section: Response At Constant š‘ƒmentioning
confidence: 56%
“…(10) where Kp represents the relative gain and provides the best dynamic performance, and Ki represents the integration gain that erases the error in the steady state. Use the traditional method the coefficients of the Kp and Ki controllers are calculated by comparing the system's total transfer function with the second-order generalized transfer [21]. In the private accounts of the shunt system active power filter pi control is necessary to set the Plosses used in pq accounts as shown in (11) [22].…”
Section: Hysteresis Band Current Controller Hbccmentioning
confidence: 99%
“…Figure 2b shows the same phasor diagram with the exception that the AcF generates the current I AcF,h = āˆ’I C,sourceāˆ’p.h , i.e., it compensates I C,sourceāˆ’p.h . The AcF reference I ref ,h is finally determined using Equation (7). For the calculation of the customer's emission in the presence of the AcF to harmonic distortion, measurements of voltage and current harmonics and their phase angles at the PCC are needed, and all impedances must be known.…”
Section: Customer's Emission In Presence Of the Active Filtermentioning
confidence: 99%
“…For example, in [2], the authors used fuzzy logic to improve the performance of a three-level AcF, and in [3], fuzzy logic was used to improve the speed and convergency (singularity problem). A pre-existing solar photovoltaic system can also be used for power quality improvement (functions of AcF), as in [4][5][6][7]. Wind power plants are connected to a grid with high-power converters that produce harmonics at relatively low frequencies [8].…”
Section: Introductionmentioning
confidence: 99%