Abstract: In this paper, shunt active power filter (SAPF) is designed to address the problem of current harmonics in the source current arising from a nonlinear load and improve the quality of electric power. That will be by compensating reactive power and harmonic currents. The PI controller responsible for DC-link energy storage tuning was developed using the Lévy flight distribution algorithm (LFA). It is a novel, previously unused optimization approach to suggest relative gain Kp and integration gain Ki gain values … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 24 publications
0
6
0
Order By: Relevance
“…The magnitude of DC-link voltage at the input of VSI should be more than twice the peak of the per-phase voltage of the three-phase system and is calculated using the following mathematical relation [6].…”
Section: Selection Of Optimal Dc-link Voltage Magnitudementioning
confidence: 99%
See 1 more Smart Citation
“…The magnitude of DC-link voltage at the input of VSI should be more than twice the peak of the per-phase voltage of the three-phase system and is calculated using the following mathematical relation [6].…”
Section: Selection Of Optimal Dc-link Voltage Magnitudementioning
confidence: 99%
“…The theoretical evolution given in [6] and [26] is taken into consideration in the transfer function of the DC-link voltage control loop. As a result, the DC-link voltage's open-loop transfer function can be presented as (14).…”
Section: Dc-link Voltage Controllersmentioning
confidence: 99%
“…Logics zero and one correspond to voltage levels of zero and +5 V respectively. The two ADCs input voltages VADC1 and VADC2 are related to k2BS by ( 22) and (23).…”
Section: Current Controller Of Bwscb-bwsrb Based Svcmentioning
confidence: 99%
“…The reactances connected in star form were used for compensating reactive currents, whereas those connected in delta for were exploited for balancing the active components of line currents. Active filters were introduced in [23] for the purposes of treating harmonic current components associating nonlinear loads, whereas in [24], a shunt active filter was provided to a single-phase converter to achieve significant reduction in harmonic current components. A DSTATCOM was introduced in [25] for power quality purposes.…”
Section: Introductionmentioning
confidence: 99%
“…In three-phase networks to reduce harmonics and compensate reactive power [11]- [13], active power filters (APFs) are widely used. Many studies and applications in this field have been performed in various research [14]- [17].…”
Section: Introductionmentioning