Real-world long-term battery longevity of Micra leadless pacemakers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 5 publications
0
3
0
1
Order By: Relevance
“…13 Another study exploring 7-year follow up of leadless pacemakers has demonstrated that the manufacturers anticipated battery life is accurate, and may provide more precise estimates when compared to the battery life predictions of traditional transvenous systems. 14 Despite their utility, leadless devices are not without their shortcomings. The Micra VR device cannot provide atrial pacing, limiting its programming to VVI and VVO.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…13 Another study exploring 7-year follow up of leadless pacemakers has demonstrated that the manufacturers anticipated battery life is accurate, and may provide more precise estimates when compared to the battery life predictions of traditional transvenous systems. 14 Despite their utility, leadless devices are not without their shortcomings. The Micra VR device cannot provide atrial pacing, limiting its programming to VVI and VVO.…”
Section: Discussionmentioning
confidence: 99%
“…One analysis has demonstrated equivalence of leadless and transvenous pacemakers over 14 months in reducing syncope frequency amongst 72 patients with a history of cardioinhibitory vasovagal syncope 13 . Another study exploring 7‐year follow up of leadless pacemakers has demonstrated that the manufacturers anticipated battery life is accurate, and may provide more precise estimates when compared to the battery life predictions of traditional transvenous systems 14 …”
Section: Discussionmentioning
confidence: 99%
“…However, the long-term experience with Micra retrieval is limited. The Micra VR was designed with 12 years of battery life, and the battery longevity was confirmed in the real-world setting [ 67 ]. As for the Micra AV, the original design of an 11.8 year battery life (1 V, 0.24 ms) with 100% pacing was reduced to 10.5 years in the real-world setting [ 68 ].…”
Section: Leadless Ventricular Pacemakersmentioning
confidence: 99%
“…konnten in einer Analyse von 153 PatientInnen mit einem Micra TM VR bei einem mittleren Follow-up von 35 Monaten (bis maximal 7 Jahre) nachweisen, dass bei einem Großteil der PatientInnen sogar mit einer Laufzeit von > 13 Jahren (bei einem medianen Stimulationsanteil von 35 % und einer stabilen mittleren Stimulationsreizschwelle von 0,7 V @0,24 ms) gerechnet werden kann. Batterieversagen im Sinne eines unvorhergesehenen signifikanten Abfalls der Batteriekapazität traten nicht auf [ 18 ]. Außerhalb Europas ist bereits derzeit eine Nachfolge-Generation des Micra TM verfügbar, Micra TM VR2 und AV2, die beide nun durch eine größere Batteriekapazität projektierte mediane Laufzeiten von 16,7 Jahren (VR) bzw.…”
Section: Laufzeitunclassified