2022
DOI: 10.1016/j.bios.2021.113803
|View full text |Cite
|
Sign up to set email alerts
|

Real-time ultra-sensitive detection of SARS-CoV-2 by quasi-freestanding epitaxial graphene-based biosensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
23
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 30 publications
(23 citation statements)
references
References 58 publications
0
23
0
Order By: Relevance
“…Other SARS-CoV-2 assays with different readouts than SERS have demonstrated to be extremely specific and sensitive. For example, S. Kim et al, reported electrical transduction of the spike protein onto a bilayer quasi-freestanding epitaxial graphene with immunodetection concentrations as low as 1 ag/ml 49 . S. Mavrikou et al .…”
Section: Resultsmentioning
confidence: 99%
“…Other SARS-CoV-2 assays with different readouts than SERS have demonstrated to be extremely specific and sensitive. For example, S. Kim et al, reported electrical transduction of the spike protein onto a bilayer quasi-freestanding epitaxial graphene with immunodetection concentrations as low as 1 ag/ml 49 . S. Mavrikou et al .…”
Section: Resultsmentioning
confidence: 99%
“…The consistency between the detection results and real‐time fluorescence quantitative PCR was 100% 57 . SARS‐CoV‐2 S1 spike protein antibodies immobilized on graphene material can capture 60 copies/mL of the virus by electrical transduction in midturbinate swabs and exhaled breath aerosol samples 58 . The B.1.1.7 mutant can be detected at 400–8000 copies/ml of the virus 58 .…”
Section: Introductionmentioning
confidence: 84%
“… 57 SARS‐CoV‐2 S1 spike protein antibodies immobilized on graphene material can capture 60 copies/mL of the virus by electrical transduction in midturbinate swabs and exhaled breath aerosol samples. 58 The B.1.1.7 mutant can be detected at 400–8000 copies/ml of the virus. 58 Furthermore, the detection reagent can be reused after elution by NaCl solution or heat treatment above 40°C.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…For intercalated EG, a shift to lower binding energy is known to occur for the C 1s Si-C and Si 2p peaks due to a difference in surface band bending after intercalation [ 39 , 41 , 42 , 43 ]. Therefore, the spectra for hydrogen-intercalated QFS bilayer EG were shifted to the position of the C 1s SiC peak at 282.6 eV [ 39 , 44 ].…”
Section: Methodsmentioning
confidence: 99%