Proceedings of SPE International Petroleum Conference and Exhibition in Mexico 2002
DOI: 10.2523/74380-ms
|View full text |Cite
|
Sign up to set email alerts
|

Real-Time, Time-Lapse Resistivity Logging With a Wired Composite Tubing

Abstract: TX 75083-3836, U.S.A., fax 01-972-952-9435. AbstractThe development of a wired composite tubing enables the continuous acquisition and transmission of petrophysical and drilling dynamics data during all phases of a drilling operation. This capability results in logging passes for each bit trip throughout the life of the well. The operator can then correlate and compare the data in real-time to better understand the borehole stability. This paper presents two case studies that illustrate the value of real-time … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2002
2002
2006
2006

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 2 publications
0
5
0
Order By: Relevance
“…However, the composite log shows the slow decrease in equivalent circulating density (ECD) back to the static pressure at a very early stage in ballooning. 5 Once the ballooning process has been identified, the correct steps can be taken to cure the fractures. Well parameters, mud weight, or drilling practices can be altered to ensure that the ballooning is minimized.…”
Section: Identify Early Development Of Borehole Ballooningmentioning
confidence: 99%
“…However, the composite log shows the slow decrease in equivalent circulating density (ECD) back to the static pressure at a very early stage in ballooning. 5 Once the ballooning process has been identified, the correct steps can be taken to cure the fractures. Well parameters, mud weight, or drilling practices can be altered to ensure that the ballooning is minimized.…”
Section: Identify Early Development Of Borehole Ballooningmentioning
confidence: 99%
“…ACCT is inert to most chemicals and does not corrode. 5 The embedded conductors in the pipe enable two-way communication with the BHA. The BHA (Fig.…”
Section: Advanced Composite Coiled Tubingmentioning
confidence: 99%
“…ACCT is inert to most chemicals and does not corrode. 4 The embedded conductors in the pipe enable two-way communication with the BHA. The BHA (Fig.…”
Section: Advanced Composite Coiled Tubingmentioning
confidence: 99%