2001
DOI: 10.1016/s0301-5629(01)00421-5
|View full text |Cite
|
Sign up to set email alerts
|

Real-time three-dimensional intracardiac echocardiography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
33
0

Year Published

2004
2004
2014
2014

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 59 publications
(34 citation statements)
references
References 12 publications
1
33
0
Order By: Relevance
“…the C-scan planes, the system also displays real time 3D rendered images. 12,14,15 The pyramid angle is typically set at 65 degrees, but we have modified the system to produce up to a 120 degree pyramidal scan for a larger field of view up close to the transducer. 16 Transducer Design For the 5 MHz laparoscope, we adapted a design we have previously used for a side viewing intracardiac catheter transducer.…”
Section: Volumetric Scanner Systemmentioning
confidence: 99%
“…the C-scan planes, the system also displays real time 3D rendered images. 12,14,15 The pyramid angle is typically set at 65 degrees, but we have modified the system to produce up to a 120 degree pyramidal scan for a larger field of view up close to the transducer. 16 Transducer Design For the 5 MHz laparoscope, we adapted a design we have previously used for a side viewing intracardiac catheter transducer.…”
Section: Volumetric Scanner Systemmentioning
confidence: 99%
“…We previously described a 12 Fr, 64 channel sideviewing catheter 2-D array operating at 5 MHz [20], [22]- [24], a 9 Fr, 70 channel side-viewing catheter 2-D array operating at 7 MHz [25], and dual-lumen, forward-viewing 2-D array probes operating at 5 MHz [26]. In this paper, we describe advances toward smaller, more clinically useful catheter 2-D arrays with increased channel counts.…”
Section: Introductionmentioning
confidence: 99%
“…In RT3D intracardiac imaging, the 2-D array transducer is miniaturized and mounted in a catheter, enabling the 3-D viewing of cardiac structures and interventional catheter devices in cross sectional and en face views [20]. Within the acquired volumes, multiple real-time B, C, or inclined planes can be displayed, as well as real time, 3-D-rendered images [21].…”
Section: Introductionmentioning
confidence: 99%
“…Transthoracic echocardiographic studies using RT3D have been effective for applications such as monitoring left ventricular function [10], detecting perfusion defects [11], and evaluating congenital abnormalities [12]. More recently, catheter-based transducers with 2-D arrays have been developed for intracardiac echocardiography [13]. These devices have been fabricated into 7F catheters with as many as 112 channels [14], successfully merging functional intracorporeal size with clinically relevant resolution for RT3D.…”
Section: Introductionmentioning
confidence: 99%