A miniaturized catheter 2-D array for real-time, 3-D intracardiac echocardiography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
51
0

Year Published

2005
2005
2023
2023

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 83 publications
(51 citation statements)
references
References 32 publications
(35 reference statements)
0
51
0
Order By: Relevance
“…It may be necessary to lodge the catheter in a stable position relative to the target cardiac structure. One possibility is to lodge the catheter in coronary sinus as shown by Lee et al [17]. Another option is to gate the therapy pulses in synchrony with an electrocardiogram.…”
Section: B Linear Phased-array Designsmentioning
confidence: 99%
See 1 more Smart Citation
“…It may be necessary to lodge the catheter in a stable position relative to the target cardiac structure. One possibility is to lodge the catheter in coronary sinus as shown by Lee et al [17]. Another option is to gate the therapy pulses in synchrony with an electrocardiogram.…”
Section: B Linear Phased-array Designsmentioning
confidence: 99%
“…echocardiography can provide views of the heart anatomy better than, or not available to, conventional transthoracic echocardiography [13], [14]. Real-time, 3-D intracardiac echocardiography catheters have visualized heart anatomy and been used to guide a number of surgical procedures in vivo in sheep, including radiofrequency ablation [15]- [17].…”
Section: Introductionmentioning
confidence: 99%
“…Extensive research efforts have been carried out to develop large-area fully populated 2D ultrasonic transducer arrays [1][2][3]. These arrays are useful in applications such as real-time 3D ultrasound echocardiography and photo-acoustic tomography.…”
Section: Introductionmentioning
confidence: 99%
“…Traditional ultrasound transducers are based on the piezoelectric technology. Electrical interconnection to array elements can be realized by mechanically dicing array elements after the piezoelectric material is bonded to a printed circuit board (PCB), which is effectively a fanout structure [1,2]. Integration to IC is indirect, through the fanout structure, which adds parasitic capacitance that degrades signal integrity.…”
Section: Introductionmentioning
confidence: 99%
“…12,14,15 The pyramid angle is typically set at 65 degrees, but we have modified the system to produce up to a 120 degree pyramidal scan for a larger field of view up close to the transducer. 16 Transducer Design For the 5 MHz laparoscope, we adapted a design we have previously used for a side viewing intracardiac catheter transducer. The transducer was designed to fit into a 10 French catheter and has 198 active elements.…”
Section: Volumetric Scanner Systemmentioning