2014 Power Systems Computation Conference 2014
DOI: 10.1109/pscc.2014.7038328
|View full text |Cite
|
Sign up to set email alerts
|

Real-time state identification for MV-grids on autonomous agent platforms

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 11 publications
0
2
0
Order By: Relevance
“…Supported by a communication infrastructure based on IEC 60870-5-104 protocol, the unit is provided with continuous measurements in the monitored grid area and capable of sending commands to actuators (variable transformers, controllable loads or feeders). Just approximately 15 % of all nodes need to be measured for sophisticating results in the state estimation by network partitioning or sensitivity analysis [8]. Together with a parameter set, containing static information on the grid (branches, feeders and topology), the cyclical updated measurement builds up the input data base for the forecast algorithm.…”
Section: Basic Conditions and Use Casementioning
confidence: 99%
See 1 more Smart Citation
“…Supported by a communication infrastructure based on IEC 60870-5-104 protocol, the unit is provided with continuous measurements in the monitored grid area and capable of sending commands to actuators (variable transformers, controllable loads or feeders). Just approximately 15 % of all nodes need to be measured for sophisticating results in the state estimation by network partitioning or sensitivity analysis [8]. Together with a parameter set, containing static information on the grid (branches, feeders and topology), the cyclical updated measurement builds up the input data base for the forecast algorithm.…”
Section: Basic Conditions and Use Casementioning
confidence: 99%
“…Initial simulative tests of the implementation in combination with the smart grid monitoring unit have been applied on a grid model, equating a real medium voltage grid that consists of 104 nodes and 105 branches. 23 measurements were determined to be installed for the state estimation by network partitioning [8]. Only the apparent powers at measured points are considered as forecasted quantities, while there is no differentiation either it is a branch or feeder measurement.…”
Section: State Forecastmentioning
confidence: 99%