2004
DOI: 10.1016/j.chemosphere.2003.10.031
|View full text |Cite
|
Sign up to set email alerts
|

Real-time-monitored decrease of trichlorophenol as a dioxin surrogate in flue gas using iron oxide catalyst

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0
1

Year Published

2007
2007
2016
2016

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(11 citation statements)
references
References 1 publication
0
10
0
1
Order By: Relevance
“…These investigated indicators include CO (Yoneda et al, 2002;Weber et al, 2002), PAHs (Li et al, 2006b;Streibel et al, 2007;Yan et al, 2010), CBz (Streibel et al, 2007;Yoneda et al, 2002;Oser et al, 1998;Zimmermann et al, 1999;Kato and Urano, 2001b), CP (Yoneda et al, 2002;Tuppurainen et al, 1999;Yamada et al, 2004), low-volatile organohalogen compounds (LVOH) (Watanabe et al, 2010;Kato et al, 2000), and some specific PCDD/F (Kato and Urano, 2001a;Gullett and Wikstrom, 2000;Iino et al, 2003). According the present study, CBz and PAHs are two indicators that are positively and strongly correlated with PCDD/Fs.…”
Section: Pcdd/fs Indicatorsmentioning
confidence: 54%
“…These investigated indicators include CO (Yoneda et al, 2002;Weber et al, 2002), PAHs (Li et al, 2006b;Streibel et al, 2007;Yan et al, 2010), CBz (Streibel et al, 2007;Yoneda et al, 2002;Oser et al, 1998;Zimmermann et al, 1999;Kato and Urano, 2001b), CP (Yoneda et al, 2002;Tuppurainen et al, 1999;Yamada et al, 2004), low-volatile organohalogen compounds (LVOH) (Watanabe et al, 2010;Kato et al, 2000), and some specific PCDD/F (Kato and Urano, 2001a;Gullett and Wikstrom, 2000;Iino et al, 2003). According the present study, CBz and PAHs are two indicators that are positively and strongly correlated with PCDD/Fs.…”
Section: Pcdd/fs Indicatorsmentioning
confidence: 54%
“…(c). The setup of the APCI source has been described in detail elsewhere . Sample gases were introduced into the corona discharge region and ionized by APCI.…”
Section: Methodsmentioning
confidence: 99%
“…Direct sampling MS, which involves minimal sample preparation and no chromatographic separation step prior to analysis by MS, has been used for real-time gas analysis such as volatile organic compounds in air, [26] dioxin precursors [27,28] and polychlorinated biphenyls [29] in incinerator flue gas. In these MS, a large volume of ambient air or flue gas was introduced into various inlet systems that served to extract and transfer analytes from ambient pressure to vacuum inside the mass spectrometer.…”
Section: Introductionmentioning
confidence: 99%