2009
DOI: 10.1038/nmeth.f.263
|View full text |Cite
|
Sign up to set email alerts
|

Real-time, label-free monitoring of cellular invasion and migration with the xCELLigence system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
57
0
1

Year Published

2011
2011
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 74 publications
(58 citation statements)
references
References 1 publication
0
57
0
1
Order By: Relevance
“…The model extends existing models of cancer cell movement (29,30) to incorporate receptor recycling and membrane regulatory effects of MYOF, based on experimental results using xCELLigence assays (27) showing that MYOF-KD MDA-MB-231 cells exhibited decreased invasivity (Figs. 3 and 4, with immunoblot validation of MYOF specific depletion shown in SI Appendix, Fig.…”
Section: Figmentioning
confidence: 91%
See 2 more Smart Citations
“…The model extends existing models of cancer cell movement (29,30) to incorporate receptor recycling and membrane regulatory effects of MYOF, based on experimental results using xCELLigence assays (27) showing that MYOF-KD MDA-MB-231 cells exhibited decreased invasivity (Figs. 3 and 4, with immunoblot validation of MYOF specific depletion shown in SI Appendix, Fig.…”
Section: Figmentioning
confidence: 91%
“…2). We used an electrode-impedance-based invasion assay [xCELLigence (27)] to probe the effect of MYOF deficiency on cell invasion. Compared to the control MBA-MB-231 cells, MYOF-knockdown (MYOF-KD) cells exhibited reduced invasive capacity (28).…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Electrical impedance indicated as cell index (CI) value and provides quantitative information about the condition of the cells, involving cell number, viability, and morphology [9] .…”
Section: Cell Proliferation Assay With Real-time Cell Analysis Systemmentioning
confidence: 99%
“…After the incubation, HUVEC cells were seeded at a 2×104 density per well onto the top chambers of CIM-16 plates in 80 μl of serum-free media, then 100 µl of HP-1 extract concentrations (25, 50, 200 µg/ml) were added. After stabilizing CIM-plates for 30 min at room temperature, the chamber was loaded in the RTCA DP machine and software was set to collect impendence data, reported as CI values, once every 10 min for 24 h [9,11] .…”
Section: Cell Migration and Invasion Assays With Real-time Cell Analymentioning
confidence: 99%