2008
DOI: 10.1007/s00247-007-0731-7
|View full text |Cite|
|
Sign up to set email alerts
|

Real-time and Doppler US after pediatric segmental liver transplantation

Abstract: An HV1/HV2 ratio of >4.1 is a highly predictive CD-US parameter for the detection of hemodynamically significant HV stenosis on angiography.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0
5

Year Published

2009
2009
2021
2021

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(18 citation statements)
references
References 14 publications
0
13
0
5
Order By: Relevance
“…The rate of stenosis was 8.4% (Table 2). In 5 patients, fortunately, stenosis was detected early by ultrasonic studies and was treated with percutaneous balloon dilatation [26]. One patient with stenosis died while waiting for retransplantation.…”
Section: Discussionmentioning
confidence: 99%
“…The rate of stenosis was 8.4% (Table 2). In 5 patients, fortunately, stenosis was detected early by ultrasonic studies and was treated with percutaneous balloon dilatation [26]. One patient with stenosis died while waiting for retransplantation.…”
Section: Discussionmentioning
confidence: 99%
“…Color Doppler US abnormalities were diagnosed when one or more of the following criteria were present in at least two consecutive examinations : hepatic artery—tardus‐parvus pattern, RI < 0.5 or >0.8, peak systolic velocity <30 cm/sec or peak focal systolic velocity >200 cm/sec, change in systolic peak velocity of >30% in comparison with previous investigations, and absence of arterial flow at the porta hepatis or at intraparenchymal level; portal vein—peak velocity <20 cm/sec, disproportional peak velocity in the portal vein compared with the splenic vein (peak portal velocity < peak splenic velocity), undulating or retrograde portal venous flow, or change in peak portal velocity > 30% in comparison with previous values; and hepatic veins—signs of hepatic outflow obstruction, loss of phasic waveform in follow‐up, and peak venous velocity >120 cm/sec.…”
Section: Methodsmentioning
confidence: 99%
“…This system allowed us to accurately set the flow splits to simulate physiological (LHV/MHV/RHV: 0.4/0.4/0.2) and pathological flow rates (LHV/MHV/RHV: 0.3/0.4/0.2) reported in literature. [27][28][29]48,69,72 The experimental flow conditions are tabulated in Table 1. These flow conditions are labeled ''healthy'' and ''pathological'' according to the clinical diagnoses of pediatric patients.…”
Section: In Vitro Flow Loopmentioning
confidence: 99%