2020
DOI: 10.1016/j.bios.2020.112372
|View full text |Cite
|
Sign up to set email alerts
|

Reactivity mapping of luminescence in space: Insights into heterogeneous electrochemiluminescence bioassays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
54
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

5
1

Authors

Journals

citations
Cited by 47 publications
(63 citation statements)
references
References 37 publications
1
54
0
Order By: Relevance
“…[11][12][13][14][15][16][17][18][19][20][21][22] The heterogeneous ECL mechanism of the [Ru(bpy) 3 ] 2+ /TPrA system is an active area of investigation. 14,32,33,43,44 In such a conguration, the ECL luminophore is not free to diffuse and cannot be directly oxidised at the electrode. 45,46 In the current system under investigation, the [Ru(bpy) 3 ] 2+ label is covalently bound to the bead as in beadbased ECL immunoassays.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…[11][12][13][14][15][16][17][18][19][20][21][22] The heterogeneous ECL mechanism of the [Ru(bpy) 3 ] 2+ /TPrA system is an active area of investigation. 14,32,33,43,44 In such a conguration, the ECL luminophore is not free to diffuse and cannot be directly oxidised at the electrode. 45,46 In the current system under investigation, the [Ru(bpy) 3 ] 2+ label is covalently bound to the bead as in beadbased ECL immunoassays.…”
Section: Resultsmentioning
confidence: 99%
“…46 Many research groups, including ours, mapped the ECL reactivity and the emission spatial distribution in such a context. 14,15,33,43 The maximum of ECL emission occurs in the micrometric region where concentrations of TPrAc and TPrAc + radicals are locally the highest. 43,44 We also demonstrated, by analysing the side-view ECL image of the beads that only luminophores located within the 3 mm region close to the electrode contribute to the signal.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…In order to measure quantitatively the effects of photobleaching on the ECL emission, it is essential that the ECL intensity does not vary due to other experimental parameters. Recently, we demonstrated that the ECL intensities of labeled cells and immunosensing beads decreased very significantly when recording consecutive ECL images [14c] . Indeed, the ECL intensity dropped by a factor 5 between the first and the second ECL image for the same labeled cell (or bead) [14c] .…”
Section: Figurementioning
confidence: 97%