2020
DOI: 10.1109/tpel.2020.2971733
|View full text |Cite
|
Sign up to set email alerts
|

Reactive Power Optimization Control for Bidirectional Dual-Tank Resonant DC–DC Converters for Fuel Cells Systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(14 citation statements)
references
References 17 publications
0
14
0
Order By: Relevance
“…Also, the analysis can be simpler based on fundamental harmonic. DAB/DAB3 converters with resonant networks have been studied for more-electric aircraft power supplies [281], [286], battery chargers [283], [287], [288], hybrid generation systems [285], energy storage [289], [306], [308], grid-connected PV system [290], [291], renewable energy generation systems [295], [296], [301], [302], [305], [313], [314], fuel cells generation system [298], SST in hybrid micro-grid [299], and V2G systems [303], [304], [311], [312].…”
Section: B Dab/dab3 With Resonant Networkmentioning
confidence: 99%
“…Also, the analysis can be simpler based on fundamental harmonic. DAB/DAB3 converters with resonant networks have been studied for more-electric aircraft power supplies [281], [286], battery chargers [283], [287], [288], hybrid generation systems [285], energy storage [289], [306], [308], grid-connected PV system [290], [291], renewable energy generation systems [295], [296], [301], [302], [305], [313], [314], fuel cells generation system [298], SST in hybrid micro-grid [299], and V2G systems [303], [304], [311], [312].…”
Section: B Dab/dab3 With Resonant Networkmentioning
confidence: 99%
“…A bi-directional power flow scheme has been proposed in [17], where the power flow between the AC main grid and DC microgrid is controlled through a DAB converter. In References [18,19], the reactive power control of a DAB converter is assessed. Reference [20] focused on reducing the current stress.…”
Section: Literature Reviewmentioning
confidence: 99%
“…The term T represents a half period, and f S is the switching frequency. If the DAB input admittance C 1 is considered part of Z out in (19), the closed-loop input impedance is obtained through:…”
Section: Stability Criteria and Impedance Modellingmentioning
confidence: 99%
See 1 more Smart Citation
“…It is presented the modeling in the frequency domain of the input DMC normalized current of a lossless DAB, in such a way that the performance characteristic of power factor and DMC normalized harmonic impacts can be observed through this suitable plane. As it is presented a lossless theory, the power factor will represent the notion of efficiency, as the amount of reactive power impacts on both the efficiency [7] and the power density, whereas the first harmonic appearing in the lower limit of the frequency spectrum represent the effort for filtering to comply with regulations. Therefore, both analysis of power factor and DMC first harmonic represent how much the converter in a general way (filter, isolation, cooling, and etc.)…”
Section: Introductionmentioning
confidence: 99%