2018
DOI: 10.3390/en11113177
|View full text |Cite
|
Sign up to set email alerts
|

Reactive Power Optimal Control of a Wind Farm for Minimizing Collector System Losses

Abstract: A reactive power/voltage control strategy is proposed that uses wind turbines as distributed reactive power sources to optimize the power flow in large-scale wind farms and reduce the overall losses of the collector system. A mathematical model of loss optimization for the wind farm collector systems is proposed based on a reactive power/voltage sensitivity analysis; a genetic algorithm (GA) and particle swarm optimization (PSO) algorithm are used to validate the optimization performances. The simulation model… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
13
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 19 publications
(18 citation statements)
references
References 21 publications
(30 reference statements)
0
13
0
1
Order By: Relevance
“…are predominately used in high voltage (HV) transmission systems. However, in recent years, there have been several contributions [2][3][4][5][6][7][8][9][10] where usage of grid-connected photovoltaic (PV) system inverters for reactive power generation (i.e., compensation) in distribution systems was proposed.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…are predominately used in high voltage (HV) transmission systems. However, in recent years, there have been several contributions [2][3][4][5][6][7][8][9][10] where usage of grid-connected photovoltaic (PV) system inverters for reactive power generation (i.e., compensation) in distribution systems was proposed.…”
Section: Introductionmentioning
confidence: 99%
“…In Reference [7] a reactive power and voltage control strategy is proposed in order to reduce overall losses in the wind farm. Reactive power/voltage sensitivity matrix is used to optimize power flows.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The PMSG is also easier than the DFIG due to the var decoupling by the B2B converters . There are already papers about var control and optimization to them, although using the simplified description of the WT without the generator and B2B converters . For the DFIG‐basedfarm, there are papers dispatching its total reactive power from system level.…”
Section: Introductionmentioning
confidence: 99%
“…[9][10][11][12] There are already papers about var control and optimization to them, although using the simplified description of the WT without the generator and B2B converters. [13][14][15] For the DFIG-basedfarm, there are papers dispatching its total reactive power from system level. Hence, the reactive power dispatch of the DFIGs in the wind farm is to be studied, which may be applied to the PMSGs, the SVCs, the shunt capacitors, or the system dispatch with multiple wind farms.…”
mentioning