Reactive power compensation in a steel industrial plant with several operating electric arc furnaces utilizing open-loop controlled TCR/FC compensators

Abstract: Electric arc furnaces (EAFs) produce voltage fluctuations and flicker because of the reactive power severe variations. Furthermore, these loads absorb a large amount of reactive power. The static VAr compensators (SVCs) have been widely used by the industrial customers with arc furnaces to compensate the reactive power due to the quick response of the power electronic devices. In this paper, reactive power compensation in the steel industrial plant with several EAFs by utilizing open-loop controlled thyristor … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 13 publications
0
6
0
Order By: Relevance
“…3. Compared with the non-linear arc models [11][12][13], the proposed model exhibits faster performance speed, since other models are either based on complex equations requiring accurate initial conditions or can only be used for a unique EAF. Also, some may be linear while others might be non-linear equations.…”
Section: Discussionmentioning
confidence: 98%
See 2 more Smart Citations
“…3. Compared with the non-linear arc models [11][12][13], the proposed model exhibits faster performance speed, since other models are either based on complex equations requiring accurate initial conditions or can only be used for a unique EAF. Also, some may be linear while others might be non-linear equations.…”
Section: Discussionmentioning
confidence: 98%
“…These loads can generate different types of disturbances and distortions such as voltage flicker, current and voltage harmonics, inter-harmonics, unbalances, sags, and swells in power systems, known as power quality (PQ) parameters. An electric arc is an electric discharge used in steel producing industries to melt scraps, direct-reduced iron (DRI), and other raw materials, along with lime and fluxes, by means of both So far, several models, such as a voltage-source model [1][2][3][4][5][6], data-based models [7], harmonic frequency models [8][9][10], and non-linear and data recording models have been presented for EAF [11][12][13].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…One of the most serious problems in such distribution grids is the voltage instability. The analysis and types of solutions for it are well defined in the literature . On the other hand, the optimum placement of an SVC to support the voltage profile among a grid is an important subject and different approaches exist .…”
Section: Introductionmentioning
confidence: 99%
“…The analysis and types of solutions for it are well defined in the literature. [27][28][29][30][31][32][33][34][35][36] On the other hand, the optimum placement of an SVC to support the voltage profile among a grid is an important subject and different approaches exist. [36][37][38][39][40][41][42] However, for the SVC system described in this paper, there was no practical alternative for the placement due to geographical, economical, and logistical reasons.…”