2000
DOI: 10.1002/(sici)1097-4628(20000509)76:6<824::aid-app8>3.0.co;2-1
|View full text |Cite
|
Sign up to set email alerts
|

Reactions taking place in the systemN,N,N′,N′,N″- pentakis(hydroxymethyl)melamine-oxirane in aqueous media

Abstract: ABSTRACT:The results of studies on effects of the amount and type of oxirane, amount of catalyst and water, and temperature on the course of reactions taking place in the system N,N,NЈ,NЈ,NЉ-pentakis(hydroxymethyl)melamine (PHMM)-oxirane carried out in aqueous media are reported. Quantitative determination of the content of functional groups present in the system and of side products formed in reactions of oxirane with water, made it possible to analyze in detail the processes taking place in the system.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2000
2000
2008
2008

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 3 publications
(1 reference statement)
0
5
0
Order By: Relevance
“…The gas chromatographic studies were done with Hewlett‐Packard, type 5890 with FID, while the identification of side products were performed using: capillary HP‐FFAP column of 10 m length and 0.53 mm diameter; 0.1 μm thickness; within the 50–220°C temperature range and 20°/min gradient, followed by 5 min heating at 240°C temperature; injector and detector temperature 220°C; 18.3 cm 3 /min helium flow rate; sample volume 0.2 μdm 3. The calibration curves were used as before 6, 7. MALDI ToF (Matrix‐Assisted Laser Desorption Ionization Time of Flight) were obtained on Voyager‐Elite Perseptive Biosystems (USA) mass spectrometer working at linear mode with delayed ion extraction, equipped with nitrogen laser working at 337 nm.…”
Section: Methodsmentioning
confidence: 99%
“…The gas chromatographic studies were done with Hewlett‐Packard, type 5890 with FID, while the identification of side products were performed using: capillary HP‐FFAP column of 10 m length and 0.53 mm diameter; 0.1 μm thickness; within the 50–220°C temperature range and 20°/min gradient, followed by 5 min heating at 240°C temperature; injector and detector temperature 220°C; 18.3 cm 3 /min helium flow rate; sample volume 0.2 μdm 3. The calibration curves were used as before 6, 7. MALDI ToF (Matrix‐Assisted Laser Desorption Ionization Time of Flight) were obtained on Voyager‐Elite Perseptive Biosystems (USA) mass spectrometer working at linear mode with delayed ion extraction, equipped with nitrogen laser working at 337 nm.…”
Section: Methodsmentioning
confidence: 99%
“…Calibration curves were used as described in the literature. [12][13][14] The IR spectra were recorded on a Specord 71 IR (Zeiss, capillary film). 1 H-NMR spectra were recorded on an 80-MHz Tesla BS 487C spectrometer (Czechoslovakia) in a DMSO-d 6 solution with HMDS as the internal standard.…”
Section: Methodsmentioning
confidence: 99%
“…To identify all the peaks in the chromatograms due to the products of oxirane with water, chromatograms were analyzed using data in the literature. [12][13][14] The chromatograms contain mainly peaks corresponding to respective glycols and a few subsequent products of addition of oxiranes to these glycols (Table IV). The amount of glycols and their subsequent products was found in the polyethers to be relatively small.…”
Section: Analysis Of Side Productsmentioning
confidence: 99%
“…These compounds can self‐condense and react with compounds containing hydroxyl, amido, or carboxyl groups. The reaction between the melamine compounds and oxiranes, such as propylene oxide and ethylene oxide, result in the formation of polyetherols, which are used in polyurethane foams 6–8. Generally, during the preparation of linear polyetherols, a large excess of oxirane is introduced into the reaction compositions to prevent undesired melamine condensation 8.…”
Section: Introductionmentioning
confidence: 99%