2003
DOI: 10.1016/s0009-2541(03)00234-1
|View full text |Cite
|
Sign up to set email alerts
|

Re–Os systematics of UB-N, a serpentinized peridotite reference material

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

7
72
0

Year Published

2003
2003
2023
2023

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 114 publications
(79 citation statements)
references
References 40 publications
7
72
0
Order By: Relevance
“…However, the digestions of UB-N, duplicate digestions of MBr bulk-275 rock samples (MBr9 and MBr16) by LTAA, and duplicates of an in-house peridotite 276 standard from Kilbourne Hole, dissolved by both LTAA and Carius tubes (Shirey and 277 Walker, 1995), performed during this study suggest that digestions in small vessels (7 278 mL) yield reproducible results. Osmium concentrations obtained during this study are 279 higher than those derived by LTAA by Meisel et al, (2003) for bulk-rock Os during this study was 0.29 ± 0.26 pg, 187 Os/ and for bulk-rock Re 3.13 ± 2.37 pg. The short-term reproducibility of the blank was 294 ± 10 % or better, but the absolute values varied between each batch of prepared 295 reagents.…”
mentioning
confidence: 44%
See 2 more Smart Citations
“…However, the digestions of UB-N, duplicate digestions of MBr bulk-275 rock samples (MBr9 and MBr16) by LTAA, and duplicates of an in-house peridotite 276 standard from Kilbourne Hole, dissolved by both LTAA and Carius tubes (Shirey and 277 Walker, 1995), performed during this study suggest that digestions in small vessels (7 278 mL) yield reproducible results. Osmium concentrations obtained during this study are 279 higher than those derived by LTAA by Meisel et al, (2003) for bulk-rock Os during this study was 0.29 ± 0.26 pg, 187 Os/ and for bulk-rock Re 3.13 ± 2.37 pg. The short-term reproducibility of the blank was 294 ± 10 % or better, but the absolute values varied between each batch of prepared 295 reagents.…”
mentioning
confidence: 44%
“…Samples were digested in an oven at 140 o C for not less than 72 hours 265 (cf. Meisel et al, 2003). The samples were removed from the oven on a daily basis, 266…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…The determination of PGEs in geological materials is difficult because of their low abundance and heterogeneous distributions and the complexity of sample preparation. Methods for dissolving geological samples and thereby for concentrating PGEs include nickel sulfide (NiS) fire assay coupled with Te coprecipitation (Jackson et al, 1990;Zhou et al, 2001;Gros et al, 2002;Juvonen et al, 2002;Sun and Sun, 2005), acid attack combined with Na 2 O 2 fusion (Morgan and Walker, 1989;Yi and Masuda, 1996;Dai et al, 2001;Qi et al, 2003Qi et al, , 2004, aqua regia dissolution in a sealed Carius tube, and high pressure asher (HPA-S) (Shirey and Walker, 1995;Cohen and Waters, 1996;Rehkämper et al, 1998;Pearson and Woodland, 2000;Brauns, 2001;Meisel et al, 2001Meisel et al, , 2003aMeisel et al, , 2003bPretorius et al, 2003;Meisel and Moser, 2004). The advantages and disadvan-bration between spikes and samples.…”
Section: Introductionmentioning
confidence: 99%
“…The advantages and disadvan-bration between spikes and samples. However, 1-2 g sample is commonly used in a Carius tube and HPA-S (Pearson and Woodland, 2000;Meisel et al, 2001Meisel et al, , 2003aMeisel et al, , 2003bMeisel and Moser, 2004), with aqua regia less than one third of the total volume of the Carius tube to avoid possible crack caused by high internal pressure in the Carius tube.…”
Section: Introductionmentioning
confidence: 99%