1987
DOI: 10.1080/09553008714550601
|View full text |Cite
|
Sign up to set email alerts
|

RBE of a Thermal Neutron Beam and the10B(n, α)7Li Reaction on Cultured B-16 Melanoma Cells

Abstract: The RBE of a thermal neutron beam and the 10B(n, alpha)7Li reaction were determined in cultured B-16 melanoma cells. The Kyoto University Research Reactor (KUR) was used as a thermal neutron source which had a very low contamination of gamma-rays and fast neutrons. The cells were irradiated with the beam in the presence or absence of 10B-boric acid. The absorbed dose from the neutron capture reaction to the cells was calculated by a method of Kitao (1975). Survival curves in both conditions had no shoulder and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
13
0

Year Published

1988
1988
2003
2003

Publication Types

Select...
5
3
1

Relationship

1
8

Authors

Journals

citations
Cited by 37 publications
(15 citation statements)
references
References 8 publications
2
13
0
Order By: Relevance
“…This is in broad agreement with the results of Fukuda et al (1987) and Kobayashi and Kandon (1982), who report an RBE of 6 for 10 B-capture products in melanoma cells, but rather higher than the value of 3.7 reported by Davies et al (1970). However, the effectiveness of the capture products depends to a large degree on the distribution of 10 B in the cell (Nakanishi et al, 1980).…”
Section: Phantom Irradiationssupporting
confidence: 91%
“…This is in broad agreement with the results of Fukuda et al (1987) and Kobayashi and Kandon (1982), who report an RBE of 6 for 10 B-capture products in melanoma cells, but rather higher than the value of 3.7 reported by Davies et al (1970). However, the effectiveness of the capture products depends to a large degree on the distribution of 10 B in the cell (Nakanishi et al, 1980).…”
Section: Phantom Irradiationssupporting
confidence: 91%
“…The 418 showed the greatest effect but barely significant changes were seen for the 96E and 96L cell lines. Neutron fluence and absorbed dose Do values were as follows: The Do neutron fluence values are comparable to those reported at Kobe for boron-10 negative experiments, but are much larger ( x 2) than those reported for BPA positive (Fukuda et al, 1987;Ichihashi et al, 1982;Nakanishi et al, 1980). Absorbed dose Do values are about a factor of two greater, but if the dose evaluation of Fukuda et al (1987) is followed for monolayer cells, then comparable Do absorbed dose values are found.…”
Section: In Vitro Low and High Let Radiation Survival Studiessupporting
confidence: 71%
“…An improved prompt gamma activation analysis facility has been constructed at MITR-I1 Date: Wed, Jan 19,1994 Current Time: 9 Beam aperture with a 15 cm sapphire single-crystal filter. The n-type Ge gamma-ray detector is shielded with 6Li enriched Li,CO, and lead.…”
Section: Boron Quantification Prompt Gamma Activation Analysismentioning
confidence: 99%