2017
DOI: 10.3390/s17030548
|View full text |Cite
|
Sign up to set email alerts
|

Ratiometric Dissolved Oxygen Sensors Based on Ruthenium Complex Doped with Silver Nanoparticles

Abstract: A ratiometric optical sensor has been developed with electrospinning processing method for dissolved oxygen measurement. The sensing film is fabricated by using silver nano-particles (Ag NPs) doped with tris(4,7-diphenyl-1,10-phenanthroline) ruthenium(II) dichloride complex (Ru(DPP)3Cl2) encapsulated in plasticized polymethyl methacrylate (PMMA). An insensitive 3-(2-benzothiazolyl)-7-(diethy lamino)-(6CI,7CI) (Coumarin6) is adopted as reference. The ratio of oxygenation is calculated at each image pixel of a 3… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
24
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(25 citation statements)
references
References 40 publications
1
24
0
Order By: Relevance
“…While the optical sensitivity of gold-ceria nanoparticles to metallic iron tiny particles is higher than for pure ceria, it is also less linear. Based on the intensity change as shown in Figure 5, the relative change in the fluorescence emissions intensity at different iron concentrations is described in Figure 7, according to the Stern-Volmer relation [19] I o /I = 1…”
Section: Resultsmentioning
confidence: 99%
“…While the optical sensitivity of gold-ceria nanoparticles to metallic iron tiny particles is higher than for pure ceria, it is also less linear. Based on the intensity change as shown in Figure 5, the relative change in the fluorescence emissions intensity at different iron concentrations is described in Figure 7, according to the Stern-Volmer relation [19] I o /I = 1…”
Section: Resultsmentioning
confidence: 99%
“…A comparison summary of the printed oxygen sensor patch with some reported oxygen sensors is shown in Table 1. It can be noticed that the printed patch has an appreciable response time and sensitivity when compared to some of the reported oxygen sensors [40][41][42][43][44][45][46] . In addition, the exibility (mechanical stability upon bending) and robustness of the printed patch was evaluated by subjecting the printed patches to various cyclic bending tests (0, 00, 200, and 300) using a micromanipulator (Universal Test Machines -eXpert 4000, ADMET), with a duty cycle of 50% and time period of 10 s (Fig.…”
Section: Resultsmentioning
confidence: 99%
“…14 The RuDpp 3 2þ displays fluorescence quenching effects to differing levels of oxygen concentration. 15,16 We analyzed the luminescence intensity at the fluorescent layer according to RuDpp 3 2þ concentration in the sol-gel solution. For the analysis, the sol-gel solution was prepared with a composition ratio of 3.79 g: 1.45 g: 0.72 g: 21.24 mg for MTMS (Methyltrimethoxysylane, Sigma-Aldrich Chemical Co.), EtOH, H 2 O, and HCl (35%), respectively.…”
Section: Fabrication Of Fluorescent Oxygen Gas Sensor Probe Modulementioning
confidence: 99%