Rapidly switching multidirectional defibrillation: Reversal of ventricular fibrillation with lower energy shocks

Abstract: Rapidly switching multidirectional shock delivery required lower shock energy for ventricular fibrillation termination and may be a safer alternative for restoring cardiac sinus rhythm.

Search citation statements

Order By: Relevance

Paper Sections

Select...
5
2
1
1

Citation Types

2
6
0
0

Year Published

Range
2016
2016
2021
2021

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

Cited by 6 publications

(8 citation statements)

References 32 publications

2
6
0
0
Order By: Relevance
How the paper below cites the one you are viewing
“…The delivered discharges in the two defibrillation modalities, and at the 3 defibrillator outputs during multidirectional stimulation, reached the same peak voltage and had similar time course at a given energy level, which eliminated a possible bias caused by variation in the pattern of stimulation in different directions and/or modalities introduced by the use of different equipments for each pathway. The cardiac impedance estimated during application of the defibrillatory pulses (61 ± 11 Ω; Viana et al, 2014) was in agreement with the standard 50 Ω resistive load assumed for development of cardiac stimulation devices (American National Standards Institute…, 1996;Associação Brasileira de Normas Técnicas…, 2005) and in the project of the present defibrillator.…”
Section: Discussion
supporting
confidence: 80%
“…Thus, multidirectional stimulation should be able to promote electrical recruitment of cells that might remain unexcited by unidirectional stimulation, thus allowing effective stimulation with lower and safer field intensities. This proposal was confirmed for both near-excitation threshold and high-intensity field stimulation of isolated cardiac myocytes (Fonseca et al, 2013) and of the whole heart in vivo (Viana et al, 2014;present study).…”
Section: Discussion
supporting
confidence: 74%
“…These results indicate that, provided that the stimulus was sufficiently short, application of defibrillatory shocks in 3 directions decreased the stimulus energy required for defibrillation, compared to the use of the conventional, unidirectional approach. For further comparison in a larger experimental sample with 20 ms-long shocks, see Viana et al (2014).…”
Section: Results
mentioning
confidence: 99%
See 2 more Smart Citations