Rapid screening of amitraz and its metabolite residues in honey using a quick, easy, cheap, effective, rugged, and safe extraction method coupled with UHPLC and Q Exactive

Abstract: A method for determining amitraz and 2,4-dimethylaniline in honey was established by using ultra-high-performance liquid chromatoghaphy and Q Exactive after applying quick, easy, cheap, effective, rugged, and safe extracting process. A suitable extraction method was designed to extract the amitraz and 2,4-dimethylaniline after a suitable amount of honey samples was dissolved. A Thermo Syncronis C 18 column (100 × 2.1 mm, 1.7 μm) was used for chromatographic separation of the samples.Then the two compounds were… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 14 publications
0
3
0
Order By: Relevance
“…Based on the chemical properties of AA and the complexity of the sample matrix, this experiment used 0.1% formic-acid–water–methanol as the mobile phase for chromatographic separation, which is a synthesis of various methods from the literature 9,17,29,30 to improve the ion response intensity and obtain enhanced peak shape. According to the characteristics of the target compound and the existing conditions, 26,31 this method selected the CAPCELL PAK ADME chromatographic column, which is a column with a stereocage-like adamantyl functional group and ultra-high surface polarity, while balancing a certain hydrophobicity. This column could achieve good retention and separation for complex samples with polar and hydrophobic compounds.…”
Section: Resultsmentioning
confidence: 99%
“…Based on the chemical properties of AA and the complexity of the sample matrix, this experiment used 0.1% formic-acid–water–methanol as the mobile phase for chromatographic separation, which is a synthesis of various methods from the literature 9,17,29,30 to improve the ion response intensity and obtain enhanced peak shape. According to the characteristics of the target compound and the existing conditions, 26,31 this method selected the CAPCELL PAK ADME chromatographic column, which is a column with a stereocage-like adamantyl functional group and ultra-high surface polarity, while balancing a certain hydrophobicity. This column could achieve good retention and separation for complex samples with polar and hydrophobic compounds.…”
Section: Resultsmentioning
confidence: 99%
“…Li and coworkers [ 30 ] collected 35 honey samples to determine the amitraz and its metabolites. They found five positive samples with amitraz or 2,4-DMA residues ( Table 4 ).…”
Section: Discussionmentioning
confidence: 99%
“…The injection volume was 2 μL. The mass spectrometry conditions referred to the method of Li et al [ 17 ] An Orbitrap Exploris 120 mass spectrometer (ThermoFisher Scientific, Santa Clara, CA, USA) was used for identification and the parameters were as follows: Sheath gas flow rate: 50 Arb, Aux gas flow rate: 15 Arb, Capillary temperature: 320 °C, Full MS resolution: 60,000, MS/MS resolution: 15,000, Collision energy: 10 ev/30 ev/60 ev in Stepped Normalized Collisional Energy (NCE) mode, Spray Voltage: 3.8 kV, (positive) or −3.4 kV (negative).…”
Section: Methodsmentioning