1995
DOI: 10.1016/0378-4347(95)00084-v
|View full text |Cite
|
Sign up to set email alerts
|

Rapid microsample analysis of imipramine and desipramine by reversed-phase high-performance liquid chromatography with ultraviolet detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
12
0

Year Published

2004
2004
2014
2014

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 22 publications
(12 citation statements)
references
References 17 publications
0
12
0
Order By: Relevance
“…Samples containing relatively high levels of metoclopramide [13][14][15], hydrochlorothiazide [16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33], imipramine [34][35][36][37][38][39][40][41][42][43][44][45] and diclofenac potassium [46][47][48][49][50][51][52][53][54][55][56][57][58] can be analysed using UV detection. Although, these methods did not present sufficient accuracy, especially at concentrations below 10 ng/ml.…”
Section: Introductionmentioning
confidence: 99%
“…Samples containing relatively high levels of metoclopramide [13][14][15], hydrochlorothiazide [16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33], imipramine [34][35][36][37][38][39][40][41][42][43][44][45] and diclofenac potassium [46][47][48][49][50][51][52][53][54][55][56][57][58] can be analysed using UV detection. Although, these methods did not present sufficient accuracy, especially at concentrations below 10 ng/ml.…”
Section: Introductionmentioning
confidence: 99%
“…In the last 10 years, only a few procedures have been developed to determine imipramine and desipramine using HPLC with UV (Hilberg et al, 1999;Theurillat and Thormann, 1998;Tanaka et al, 1997;Yoo et al, *Correspondence to: J. Esteve-Romero, Àrea de Química Analítica, Universitat Jaume I, Campus Riu Sec, Av. de Vicent Sos Baynat, s/n 12071 Castelló, Spain.…”
Section: Introductionmentioning
confidence: 99%
“…E-mail: estevej@exp.uji.es 1995; Goldnik et al, 1991;Segatti et al, 1991) or electrochemical (Ivandini et al, 2002;Koyama et al, 1993;Bouquet et al, 1992;Foglia et al, 1991) detection. In all cases, the procedure requires prior extraction and in most of them an internal standard is used (Theurillat and Thormann, 1998;Yoo et al, 1995;Goldnik et al, 1991;Segatti et al, 1991;Koyama et al, 1993;Bouquet et al, 1992;Foglia et al, 1991). The columns used were C 18 (Theurillat and Thormann, 1998;Yoo et al, 1995;Koyama et al, 1993;Foglia et al, 1991), C 8 (Tanaka et al, 1997;Segatti et al, 1991) and cyano (Hilberget al, 1999;Foglia et al, 1991).…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations