2020
DOI: 10.1016/j.aca.2019.12.046
|View full text |Cite
|
Sign up to set email alerts
|

Rapid, hand-held paper diagnostic for measuring Fibrinogen Concentration in blood

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
11
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(11 citation statements)
references
References 57 publications
0
11
0
Order By: Relevance
“…In our previous handheld diagnostic, we tested a wide variety of blood conditions. We found that it is not impacted by common conditions such as acidosis, blood alcohol, hypertriglyceridemia, hemolysis, and warfarin administration . However, it is impacted by the presence of thrombin inhibitors.…”
Section: Discussionmentioning
confidence: 69%
See 2 more Smart Citations
“…In our previous handheld diagnostic, we tested a wide variety of blood conditions. We found that it is not impacted by common conditions such as acidosis, blood alcohol, hypertriglyceridemia, hemolysis, and warfarin administration . However, it is impacted by the presence of thrombin inhibitors.…”
Section: Discussionmentioning
confidence: 69%
“…We also tested the effect of temperature in our previous diagnostic. We found that the test is unaffected by temperatures ranging from 7 to 36 °C . However, at extreme temperatures (i.e., 44 °C), the test wicks further than normal and hence needs a means of protection.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…It was capable of reliable measurement of fibrinogen at all concentrations across the full range found in human plasma and is suitable for both hyper- and hypofibrinogenemic conditions, which is in contrast to the very narrow assay range of other recent work. 16 , 17 In addition, the method used here was a simple, robust, and single step, making it more user-friendly, while its design makes it less-prone to errors and interference. It is also compact, portable, and instrument-free, making it highly suited to point-of-care application.…”
Section: Resultsmentioning
confidence: 99%
“…16 A similar approach exploited the resulting differences in hydrophobicity of the paper when exposed to samples of different fibrinogen concentrations, which altered the distance travelled by a dye applied to the paper following sample application. 17 This method could only measure fibrinogen at <2 mg/mL. Both methods require multistep procedures and have the potential to be prone to many interferences such as variations in sample viscosity.…”
mentioning
confidence: 99%