2013
DOI: 10.1016/j.ijpharm.2012.12.019
|View full text |Cite
|
Sign up to set email alerts
|

Rapid determination of the encapsulation efficiency of a liposome formulation using column-switching HPLC

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
20
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 36 publications
(21 citation statements)
references
References 33 publications
1
20
0
Order By: Relevance
“…26) However, method verification was additionally conducted with respect to recovery of DXR from EPC and EPC+ HSPC liposome formulations because the detailed lipid components were different from the previous one. Recovery of DXR from Doxil ® was validated in the previous study.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…26) However, method verification was additionally conducted with respect to recovery of DXR from EPC and EPC+ HSPC liposome formulations because the detailed lipid components were different from the previous one. Recovery of DXR from Doxil ® was validated in the previous study.…”
Section: Resultsmentioning
confidence: 99%
“…We previously reported the methodology of the column-switching HPLC system in detail. 26) A sche- matic representation of the column-switching HPLC system is shown in Fig. A1.…”
Section: Preparation Of Dxr Liposomesmentioning
confidence: 99%
“…It generally allows the full automation of the analytical procedure and hence, a strong reproducibility. Moreover, SPE has already been successfully applied for liposomes (8,9), suggesting that it may be suitable for lipid nanoparticles (LNP) as well. This paper deals with the development of SPE 6 methods to quantify separately free and entrapped cyclosporine A in a patented nanocarrier: Lipidot ® (10).…”
Section: Introductionmentioning
confidence: 99%
“…Dialysis and gel filtration can separate these two types of drugs on the basis of difference in particle size, and ultracentrifugation is based on difference in density. In addition, we previously reported a column-switching HPLC system that separates unloaded drug and encapsulated drug in liposomal formulation or plasma, using doxorubicin as a model low molecular weight drug (Ohnishi et al, 2013;Yamamoto et al, 2011). The column-switching HPLC system can automatically separate and evaluate unloaded and encapsulated drugs in liposomal formulations on the basis of difference in hydrophobic interaction in a solid-phase extraction (SPE) column.…”
mentioning
confidence: 99%
“…The fundamental principle of the columnswitching HPLC system was previously reported (Ohnishi et al, 2013). A schematic representation of the column-switching HPLC system and the optimized operating conditions are shown in Supplementary Fig.…”
mentioning
confidence: 99%