2018
DOI: 10.1016/j.jpba.2018.02.028
|View full text |Cite
|
Sign up to set email alerts
|

Rapid determination of neomycin in biological samples using fluorescent sensor based on quantum dots with doubly selective binding sites

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(16 citation statements)
references
References 28 publications
0
16
0
Order By: Relevance
“…MIPs are polymers processed using molecularly imprinted techniques that leave cavities in the polymer matrix and have an affinity for the template molecules. For the FL sensing of AGs, FL-emitting nanomaterials such as QDs [29][30][31] and FL-emitting metal-organic framework (MOF) NPs [32] have been employed as supports to construct MIPs. Typically, He and Du's group fabricated a MIP-coated europium metal-organic framework by using 4-vinylpyridine as the main monomer, ethylene glycol dimethacrylate as the cross-linking monomer, and lincomycin as the template.…”
Section: Turn-off Fluorescent Analysis Strategiesmentioning
confidence: 99%
See 1 more Smart Citation
“…MIPs are polymers processed using molecularly imprinted techniques that leave cavities in the polymer matrix and have an affinity for the template molecules. For the FL sensing of AGs, FL-emitting nanomaterials such as QDs [29][30][31] and FL-emitting metal-organic framework (MOF) NPs [32] have been employed as supports to construct MIPs. Typically, He and Du's group fabricated a MIP-coated europium metal-organic framework by using 4-vinylpyridine as the main monomer, ethylene glycol dimethacrylate as the cross-linking monomer, and lincomycin as the template.…”
Section: Turn-off Fluorescent Analysis Strategiesmentioning
confidence: 99%
“…The LOD for lincomycin was calculated to be 16.2 nM [32]. In addition, dual recognition MIPs have been constructed for highly specific sensing of AGs [29,30]. For example, a dual-recognition MIP was constructed for the highly specific sensing of kanamycin by using CdSe QDs as supports, methacrylic acid, and thiol-modified aptamers as functional monomers.…”
Section: Turn-off Fluorescent Analysis Strategiesmentioning
confidence: 99%
“…To address this problem, combining sample pretreatment with the detection process could be an alternative choice. To determine neomycin in pork, swine liver and kidney, fish meat and liver, chicken meat and kidney, and milk samples, the samples were firstly pre-treated by liquid-liquid extraction and solidphase extraction to isolate and concentrate neomycin, and then subjected to the MIFN sensor and HPLC-FLD analysis, respectively [63] . The results indicated that both the sensitivity and selectivity of the MIFN sensor were higher than those of HPLC-FLD.…”
Section: Detection Of the Veterinary Drugs Residuesmentioning
confidence: 99%
“…As detailed in other sections, it is common to add components to MIP that improve selective recognition, usually by double recognition. Wan et al [128] developed a fluorescent sensor based on CdTe QDs with doubly selective binding sites for determination of neomycin. The QDs were encapsulated in SiO 2 and then a silica-based MIP was fabricated using a silane boronate monomer, that covalently recognizes the analyte, while the rest of the monomers allowed non-covalent recognition.…”
Section: Three-dimensional Compositesmentioning
confidence: 99%