2009
DOI: 10.1539/joh.m9003
|View full text |Cite
|
Sign up to set email alerts
|

Rapid and Effective Speciation Analysis of Arsenic Compounds in Human Urine using Anion‐Exchange Columns in HPLC‐ICP‐MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
27
2

Year Published

2010
2010
2024
2024

Publication Types

Select...
6
1
1

Relationship

2
6

Authors

Journals

citations
Cited by 25 publications
(31 citation statements)
references
References 12 publications
2
27
2
Order By: Relevance
“…T-As in urine of the first sample was 1607.2 µg/l but Ga was not detected (< 0.14 µg/l). The AsV, AsIII, and MMA concentrations were 7, 41, and 51 times higher than those of reference values of 1.7, 5.4, and 6.2 µg/l obtained in our previous study (Suzuki et al, 2009), respectively. After discharge, he took a 10-day holiday and moved to a factory with no arsine so his As concentrations had decreased to close to the reference levels by 68 days after exposure.…”
Section: Resultscontrasting
confidence: 68%
See 1 more Smart Citation
“…T-As in urine of the first sample was 1607.2 µg/l but Ga was not detected (< 0.14 µg/l). The AsV, AsIII, and MMA concentrations were 7, 41, and 51 times higher than those of reference values of 1.7, 5.4, and 6.2 µg/l obtained in our previous study (Suzuki et al, 2009), respectively. After discharge, he took a 10-day holiday and moved to a factory with no arsine so his As concentrations had decreased to close to the reference levels by 68 days after exposure.…”
Section: Resultscontrasting
confidence: 68%
“…Only AsBe was detected in the serum 110 days later. AsBe is frequently ingested by humans via the consumption of seafood and excreted unchanged in urine (Le et al, 1994), therefore, the concentration is the highest among As compounds in the urine of ordinary Japanese (Suzuki et al, 2009). On the contrary, the concentration of AsBe in the serum and urine of the patient were very low during admission and at the time of discharge because he had IVH during hospitalization while fasting.…”
Section: Resultsmentioning
confidence: 99%
“…Currently, high-performance liquid chromatography with inductively coupled plasma mass spectrometry (HPLC-ICP-MS) is the mainstay of speciation analyses of arsenic in biological samples because of its sensitivity and effectiveness 5,7) . However, it is a remarkably expensive and complicated system, and hence it is not commonly used in many laboratories.…”
Section: Development Of An Analyticalmentioning
confidence: 99%
“…On HD 2, the total concentration of inorganic arsenic and methylated metabolites thereof (92.8 µ g As/l) was above the 35 µ g As/l set as the ACGIH BEI. In addition, the sum of the concentration of inorganic arsenic and MMA is considered to be a good biological indicator of inorganic exposure among people generally taking seafoods 11) . The sum (15.3 µ g As/l) of the AsIII and MMA concentration of HD 2 was higher than 95th percentile of the general population (12.6 µ g/l), but those on HD7 and HD12 were almost the 75th percentile 11) .…”
Section: Discussionmentioning
confidence: 99%
“…In addition, the sum of the concentration of inorganic arsenic and MMA is considered to be a good biological indicator of inorganic exposure among people generally taking seafoods 11) . The sum (15.3 µ g As/l) of the AsIII and MMA concentration of HD 2 was higher than 95th percentile of the general population (12.6 µ g/l), but those on HD7 and HD12 were almost the 75th percentile 11) . In particular, an MMA level higher than that of inorganic arsenic indicates inorganic exposure based on inorganic arsenic metabolism 12) .…”
Section: Discussionmentioning
confidence: 99%