Raman spectroscopy detects deterioration in biomechanical properties of bone in a glucocorticoid-treated mouse model of rheumatoid arthritis

Abstract: Abstract. Although glucocorticoids are frequently prescribed for the symptomatic management of inflammatory disorders such as rheumatoid arthritis, extended glucocorticoid exposure is the leading cause of physician-induced osteoporosis and leaves patients at a high risk of fracture. To study the biochemical effects of glucocorticoid exposure and how they might affect biomechanical properties of the bone, Raman spectra were acquired from ex vivo tibiae of glucocorticoid-and placebo-treated wild-type mice and a … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
43
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
7
1

Relationship

4
4

Authors

Journals

citations
Cited by 37 publications
(43 citation statements)
references
References 40 publications
0
43
0
Order By: Relevance
“…RS sensitivity to glucocorticoid-treatment in rheumatoid arthritis bone shows compositional difference despite normalization to Amide I when using a fiber optic (polarization insensitive) system. 26 These biomechanical correlations are likely separate and distinct from RS correlations to collagen tension changes seen in formal polarization analysis. 36 Given low instrument polarization and results from less polarization sensitive carbonate and Amide III bands, analysis of bone from osteoarthritic patients on different load bearing surfaces can be interpreted as a largely compositional effect.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…RS sensitivity to glucocorticoid-treatment in rheumatoid arthritis bone shows compositional difference despite normalization to Amide I when using a fiber optic (polarization insensitive) system. 26 These biomechanical correlations are likely separate and distinct from RS correlations to collagen tension changes seen in formal polarization analysis. 36 Given low instrument polarization and results from less polarization sensitive carbonate and Amide III bands, analysis of bone from osteoarthritic patients on different load bearing surfaces can be interpreted as a largely compositional effect.…”
Section: Discussionmentioning
confidence: 99%
“…Spectra were then binned to a resolution of 3 cm −1 , and processed via least squares modified polynomial fit 39 and smoothed for noise using an 2nd order Savitsky-Golay filter. 26,40 After fluorescence subtraction, a linear baseline subtraction (based on derivative zero-crossings neighboring the peak) was conducted on peaks that overlap with other constituents to ensure no residual fluorescence, namely Proline, Hydroxyproline, ν1 Phosphate, and Carbonate. Spatial resolution for each objective used was approximated via edge detection on a polished silicon standard.…”
Section: Raman Instrumentationmentioning
confidence: 99%
See 1 more Smart Citation
“…PLS can also be trained to predict non-chemical properties of the sample. For example, Maher et al used PLS and Raman spectroscopy to measure bone strength [502] and Duraipandian et al estimated the probability of future development of cancer [503].…”
Section: Partial Least Squares Regressionmentioning
confidence: 99%
“…For instance, optical coherence tomography (OCT) can measure depth-resolved tissue morphology up to one millimeter below the tissue surface [3,4] depending upon the type of tissue and its associated optical properties. Chemically-sensitive optical methods, such as Raman spectroscopy (RS) [5][6][7][8][9][10][11], can measure spatiotemporal distributions of analytes with up to micron-level spatial resolution when utilizing confocal detection [12]. In fact, confocal Raman spectroscopy has been recently applied, using commercially-available instrumentation, to detect Tenofovir in tissue samples ex vivo [13].…”
Section: Introductionmentioning
confidence: 99%