1992
DOI: 10.1097/00000542-199212000-00007
|View full text |Cite
|
Sign up to set email alerts
|

Radiologic Localization of the Laryngeal Mask Airway in Children

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

9
60
1

Year Published

1994
1994
2014
2014

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 101 publications
(70 citation statements)
references
References 0 publications
9
60
1
Order By: Relevance
“…7 In children especially, down folding of the epiglottis, obscuring, but not obstructing the glottis, is a common finding on a fibrescope view through the LMA. 8,9 The size 2 PLMA differs from the adult PLMA not only in size but in design. It has an esophageal drain tube, an integrated bite block and a detachable metal introducer, but lacks the dorsal cuff extension which is thought to be important in maintaining pharyngeal seal during IPPV.…”
Section: Méthodementioning
confidence: 99%
“…7 In children especially, down folding of the epiglottis, obscuring, but not obstructing the glottis, is a common finding on a fibrescope view through the LMA. 8,9 The size 2 PLMA differs from the adult PLMA not only in size but in design. It has an esophageal drain tube, an integrated bite block and a detachable metal introducer, but lacks the dorsal cuff extension which is thought to be important in maintaining pharyngeal seal during IPPV.…”
Section: Méthodementioning
confidence: 99%
“…There is speculation from the present investigation that potentially could result in the correlation of these novel ENLs and individual patient demographic factors. Laryngeal morphology is complex with many variables which should be taken into consideration in order to accurately predict such laryngeal structure and airway size, as well as appropriate sizing of EADs [15][16][17], and further studies are currently under investigation, with some given preliminary results [18][19].…”
Section: Discussionmentioning
confidence: 99%
“…Many morbidities arise from reduced mucosal blood flow because of the raised intracuff pressure and high filling volumes [3,4]. Although the laryngeal mask airway sealing pressure is higher in smaller sized devices [15][16][17][18], a correlation between sealing pressure and position of the cuff has not been established [19]. Moreover, adequacy of ventilation does not necessarily correlate with ideal positioning based both on fibreoptic and radiological assessment [3,4,14].…”
Section: ó 2008 the Authorsmentioning
confidence: 99%