2015
DOI: 10.1177/1071100715585561
|View full text |Cite
|
Sign up to set email alerts
|

Radiographic Outcomes of Preoperative CT Scan–Derived Patient-Specific Total Ankle Arthroplasty

Abstract: Level IV, retrospective case series.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
53
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 70 publications
(58 citation statements)
references
References 21 publications
(27 reference statements)
5
53
0
Order By: Relevance
“…Apart from orthopedics (guides for knee arthroplasties), 3D-printed surgical guides were also used in neurosurgery, dental surgery, spinal surgery, and maxillofacial surgery. 28 of the 53 studies that mentioned reduced operation room time also supported this claim with numbers or statistics [ 39 , 74 , 81 , 84 , 118 , 131 , 132 , 135 , 136 , 140 , 141 , 145 , 151 , 152 , 162 , 175 , 177 , 181 , 190 , 194 , 196 , 200 , 207 , 210 212 , 219 ]. Increased procedural time was seen in seven papers, of which five supported this with numbers or statistics [ 62 , 73 , 125 , 143 , 153 , 161 , 225 ].…”
Section: Resultsmentioning
confidence: 87%
“…Apart from orthopedics (guides for knee arthroplasties), 3D-printed surgical guides were also used in neurosurgery, dental surgery, spinal surgery, and maxillofacial surgery. 28 of the 53 studies that mentioned reduced operation room time also supported this claim with numbers or statistics [ 39 , 74 , 81 , 84 , 118 , 131 , 132 , 135 , 136 , 140 , 141 , 145 , 151 , 152 , 162 , 175 , 177 , 181 , 190 , 194 , 196 , 200 , 207 , 210 212 , 219 ]. Increased procedural time was seen in seven papers, of which five supported this with numbers or statistics [ 62 , 73 , 125 , 143 , 153 , 161 , 225 ].…”
Section: Resultsmentioning
confidence: 87%
“…These results also support the emphasis on the manufacture of talar components of patient-specific size for use in total ankle arthroplasty implants [29]. Even if the measurement of the ankle-related bones had been done for the sizing of implant in the total ankle arthroplasty, Hsu et al found that talar implant sizing was not as accurate due to individual surgeon preference regarding the extent of gutter debridement [30]. Based on the results of the present study, measurement of the contralateral talus may not be the only useful method for determining the size of the talus of interest.…”
Section: Plos Onementioning
confidence: 61%
“…The use of computer-aided surgery and custom-made cutting guides have been proposed in recent years to improve surgical technique, implant positioning, and theoretically clinical outcomes [10,11]. However, there is still no clear evidence about which type of instrument or device is capable of providing better clinical results [12].…”
Section: Discussionmentioning
confidence: 99%
“…Even a small malpositioning of the implant components has a relevant impact on motion and contact pressure, which may lead ultimately to failure [9]. Great efforts have been devoted to improving surgical techniques and implant positioning, including the use of computer-aided surgery and custom cutting guides, supported also by imaging from computed tomography (CT) scans and by preoperative planning software [10]. In particular, personalized cutting guides, also known in general as patient-specific instrumentation (PSI), are customized with respect to each patient anatomy and are expected to provide more accurate component positioning [11].…”
Section: Introductionmentioning