In 1879, the French surgeon Segond described the existence of a 'pearly, resistant, fibrous band' at the anterolateral aspect of the human knee, attached to the eponymous Segond fracture. To date, the enigma surrounding this anatomical structure is reflected in confusing names such as '(mid-third) lateral capsular ligament', 'capsulo-osseous layer of the iliotibial band' or 'anterolateral ligament', and no clear anatomical description has yet been provided. In this study, the presence and characteristics of Segond's 'pearly band', hereafter termed anterolateral ligament (ALL), was investigated in 41 unpaired, human cadaveric knees. The femoral and tibial attachment of the ALL, its course and its relationship with nearby anatomical structures were studied both qualitatively and quantitatively. In all but one of 41 cadaveric knees (97%), the ALL was found as a well-defined ligamentous structure, clearly distinguishable from the anterolateral joint capsule. The origin of the ALL was situated at the prominence of the lateral femoral epicondyle, slightly anterior to the origin of the lateral collateral ligament, although connecting fibers between the two structures were observed. The ALL showed an oblique course to the anterolateral aspect of the proximal tibia, with firm attachments to the lateral meniscus, thus enveloping the inferior lateral geniculate artery and vein. Its insertion on the anterolateral tibia was grossly located midway between Gerdy's tubercle and the tip of the fibular head, definitely separate from the iliotibial band (ITB). The ALL was found to be a distinct ligamentous structure at the anterolateral aspect of the human knee with consistent origin and insertion site features. By providing a detailed anatomical characterization of the ALL, this study clarifies the long-standing enigma surrounding the existence of a ligamentous structure connecting the femur with the anterolateral tibia. Given its structure and anatomic location, the ALL is hypothesized to control internal tibial rotation and thus to affect the pivot shift phenomenon, although further studies are needed to investigate its biomechanical function.
Background Most knee surgeons have believed during TKA neutral mechanical alignment should be restored.
One year after treatment, characterized chondrocyte implantation was associated with a tissue regenerate that was superior to that after microfracture. Short-term clinical outcome was similar for both treatments. The superior structural outcome may result in improved long-term clinical benefit with characterized chondrocyte implantation. Long-term follow-up is needed to confirm these findings.
BackgroundThree-dimensional (3D) printing has numerous applications and has gained much interest in the medical world. The constantly improving quality of 3D-printing applications has contributed to their increased use on patients. This paper summarizes the literature on surgical 3D-printing applications used on patients, with a focus on reported clinical and economic outcomes.MethodsThree major literature databases were screened for case series (more than three cases described in the same study) and trials of surgical applications of 3D printing in humans.Results227 surgical papers were analyzed and summarized using an evidence table. The papers described the use of 3D printing for surgical guides, anatomical models, and custom implants. 3D printing is used in multiple surgical domains, such as orthopedics, maxillofacial surgery, cranial surgery, and spinal surgery. In general, the advantages of 3D-printed parts are said to include reduced surgical time, improved medical outcome, and decreased radiation exposure. The costs of printing and additional scans generally increase the overall cost of the procedure.Conclusion3D printing is well integrated in surgical practice and research. Applications vary from anatomical models mainly intended for surgical planning to surgical guides and implants. Our research suggests that there are several advantages to 3D-printed applications, but that further research is needed to determine whether the increased intervention costs can be balanced with the observable advantages of this new technology. There is a need for a formal cost–effectiveness analysis.Electronic supplementary materialThe online version of this article (doi:10.1186/s12938-016-0236-4) contains supplementary material, which is available to authorized users.
O ur purpose was to determine the mechanism which allows the maximum knee flexion in vivo after a posterior-cruciate-ligament (PCL)-retaining total knee arthroplasty. Using three-dimensional computer-aided design videofluoroscopy of deep squatting in 29 patients, we determined that in 72% of knees, direct impingement of the tibial insert posteriorly against the back of the femur was the factor responsible for blocking further flexion.In view of this finding we defined a new parameter termed the 'posterior condylar offset'. In 150 consecutive arthroplasties of the knee, the magnitude of posterior condylar offset was found to correlate with the final range of flexion. Total knee arthroplasty (TKA) gives good subjective and objective results during the first 15 years after implantation. Nevertheless, it is clear that the function and subjective findings do not match those of the normal knee. The range of flexion of the knee obtained after TKA is often limited and may be determined by several factors, including the length of the quadriceps, capsular tightness, surgical technique, postoperative physiotherapy and the design of the implant.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.