2021
DOI: 10.1055/a-1387-7880
|View full text |Cite
|
Sign up to set email alerts
|

Radiofrequency ablation for intraductal extension of ampullary adenomatous lesions: proposal for a standardized protocol

Abstract: Background and study aims Intraductal extension of ampullary adenoma represents a challenging endoscopic issue. Intraductal radiofrequency ablation (RFA) has been recently suggested, but evidence and standardization of this technique are still lacking. This study aimed to provide a long-term evaluation of clinical efficacy and safety of intraductal RFA ablation with a standardized algorithm of treatment. Patients and methods Data were prospectively collected from consecutive patients with intraductal… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 24 publications
(52 reference statements)
0
7
0
Order By: Relevance
“…(Figure 1) A total of 12 were utilized for qualitative synthesis and 7 for quantitative synthesis, totaling 124 patients. [12][13][14][15][23][24][25] Five studies were excluded from the quantitative analysis due to duplicate data (Table 2).…”
Section: Results Of Searches and Characteristics Of The Included Studiesmentioning
confidence: 99%
See 2 more Smart Citations
“…(Figure 1) A total of 12 were utilized for qualitative synthesis and 7 for quantitative synthesis, totaling 124 patients. [12][13][14][15][23][24][25] Five studies were excluded from the quantitative analysis due to duplicate data (Table 2).…”
Section: Results Of Searches and Characteristics Of The Included Studiesmentioning
confidence: 99%
“…The VIVA Combo generator (STARmed, Seoul, South Korea) was employed for intraductal RFA delivery, providing precise control over power settings, target temperature, and impedance. [14,15,23] The Habib catheter it is an 8 French (2.7 mm) sizable bipolar RFA probe, extending 180 cm in length, and is equipped with two ring electrodes that are spaced 8 mm apart, and the distal electrode is positioned 5 mm from the front edge. The catheter was attached to an electrosurgical generator, with options including the RITA 1500X from Angiodynamics in Latham, NY, the Erbe system from Surgical Technology Group in Hampshire, England, U.K., or the Beamer from ConMed.…”
Section: Radiofrequency Ablationmentioning
confidence: 99%
See 1 more Smart Citation
“…In recent years, radiofrequency ablation (RFA) of the bile duct has been commercially available. In two studies, the efficacy of intraductal RFA was 75% and 92.3% respectively [40,41]. A single session of RFA eradicated dysplasia in 70% patients at 12 months follow up.…”
Section: Management Ampullary Adenomasmentioning
confidence: 99%
“…One patient died from a severe acute pancreatitis. We reported 3 early complications (two pancreatis whom one mild and one fatal and one bleeding) (12%) and twelve late complications (48%) of a stenosis type, successfully managed endoscopically 1 2 3 .…”
mentioning
confidence: 96%