2009
DOI: 10.1016/j.asr.2009.02.003
|View full text |Cite
|
Sign up to set email alerts
|

Radiation measured during ISS-Expedition 13 with different dosimeters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 22 publications
(11 citation statements)
references
References 25 publications
0
11
0
Order By: Relevance
“…In LEO, · D varies from 0.058 Gy y −1 to 0.12 Gy y −1 , · H varies from 0.17 Sv y −1 to 0.30 Sv y −1 , and À Q varies from 2.5 to 3.1 (Zhou et al 2007(Zhou et al , 2009a(Zhou et al , 2009b. Such a similarity means operational radiation procedures currently in place may only need minor revision to be applicable to the radiation environment on the surface of Mars.…”
Section: Free Space/surface Of Mars Comparisonmentioning
confidence: 94%
See 1 more Smart Citation
“…In LEO, · D varies from 0.058 Gy y −1 to 0.12 Gy y −1 , · H varies from 0.17 Sv y −1 to 0.30 Sv y −1 , and À Q varies from 2.5 to 3.1 (Zhou et al 2007(Zhou et al , 2009a(Zhou et al , 2009b. Such a similarity means operational radiation procedures currently in place may only need minor revision to be applicable to the radiation environment on the surface of Mars.…”
Section: Free Space/surface Of Mars Comparisonmentioning
confidence: 94%
“…A TEPC was chosen for this study because of its simplicity and its extensive use on board International Space Station (ISS) and Space Shuttle missions (Zhou et al 2007(Zhou et al , 2009a(Zhou et al , 2009b. Additionally, FLUKA's ability to simulate the response of a TEPC has been well documented.…”
mentioning
confidence: 99%
“…Charged particles can be identified by measuring effective etch rate ratio S eff and fractional etch rate gradient G (g À1 cm 2 ), as described in Fowler (Fowler et al, 1976); O'Sullivan (O'Sullivan et al, 1999(O'Sullivan et al, , 2004 and Zhou (Zhou et al, 2006(Zhou et al, , 2007(Zhou et al, , 2009a. The method of G-S eff to identify HZE particles using CR-39 detectors is described fully in these publications so that here we will discuss only the results obtained.…”
Section: Charge Identification For the Selected Test Gcr Eventsmentioning
confidence: 98%
“…The scanned data were then analyzed and LET spectra (differential and integral fluence, dose and dose equivalent) were obtained based on the LET spectrum method using CR-39 detectors (O'Sullivan et al, 1999(O'Sullivan et al, , 2004Zhou et al, 2006Zhou et al, , 2007Zhou et al, , 2009a.…”
Section: Data Scan and Analysismentioning
confidence: 99%
“…These fragmentation reactions thus change the physical and biological effectiveness of radiation. Light hydrogenated materials, such as water and polyethylene are mostly used to study physical and biological effects of space radiation [12][13][14][15] and liquid hydrogen is the second best shielding material against GCR [1]. A better protection from meteoroids and debris in low earth orbits could be provided by composite materials such as nextel and kevlar [6].…”
Section: Introductionmentioning
confidence: 99%