2020
DOI: 10.1016/j.ejmp.2020.08.020
|View full text |Cite
|
Sign up to set email alerts
|

Radiation dose monitoring in computed tomography: Status, options and limitations

Abstract: In the last few years there has been an increasing interest on radiation dose to patients undergoing various diagnostic or therapeutic procedures with the use of ionizing radiation. Especially for CT examinations and interventional procedures, where it is known that patient doses are much higher than conventional radiography, new norms have been published that require to have appropriate radiation dose indices registered in the patient medical record. Because of these demands, dose monitoring has been recommen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
16
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 23 publications
(17 citation statements)
references
References 63 publications
0
16
0
1
Order By: Relevance
“…Some of them rely on patient dimensions calculated from CT radiographs, but some can calculate water equivalent diameter from axial images. [23][24][25] The Deff for chest examination can be corrected for the presence of lung tissue to give a more accurate estimation of SSDE. 26 Approximating Deff using only one dimension, AP or LAT, would be very helpful in the clinical environment so that it could be estimated from the CT radiograph which is usually scanned in one direction.…”
Section: Discussionmentioning
confidence: 99%
“…Some of them rely on patient dimensions calculated from CT radiographs, but some can calculate water equivalent diameter from axial images. [23][24][25] The Deff for chest examination can be corrected for the presence of lung tissue to give a more accurate estimation of SSDE. 26 Approximating Deff using only one dimension, AP or LAT, would be very helpful in the clinical environment so that it could be estimated from the CT radiograph which is usually scanned in one direction.…”
Section: Discussionmentioning
confidence: 99%
“…Conventional ionization chambers cannot be used to measure the absorbed dose as large beamwidths in CT scanners with multiple beam apertures are present. When a typical CT chamber (10cm) is used to determine the absorbed dose improperly, the dose profile for wide beams is likely to be underestimated [20], [21]. These patient dose problems can be easily addressed with a solid-state dosimetry CT dose profiler made by RTI Group Electronic, Sweden.…”
Section: Ct Radiation Dosimetrymentioning
confidence: 99%
“…I.A. Tsalafoutas et al [16] review the various steps of the introduction of the specific CT-dose quantities, their definition, measurement and recording. Recent solutions are presented like the concept of computer-based dose monitoring systems (DMS) which enables automatization of dose monitoring and recording for each examination, and beyond that a systematic analysis of the captured data to optimize the examination protocols.…”
Section: X-ray Dosimetry and Radioprotectionmentioning
confidence: 99%