2013
DOI: 10.1111/aogs.12246
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative sonoelastography of the uterine cervix by interposition of a synthetic reference material

Abstract: The reference cap constitutes a promising tool for quantitative elastography of the anterior cervical lip. Figures obtained from the posterior cervical lip are less plausible due to the distance from the transducer and the heterogeneity introduced by the cervical canal. The method has the potential to be used to supplement cervical length assessment when evaluating women at risk of preterm delivery and when planning induction of labor.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
23
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 34 publications
(23 citation statements)
references
References 15 publications
0
23
0
Order By: Relevance
“…Interesting is the approach proposed by the Danish group, which proposed to overcome the problem of the exerted force by positioning a reference cup with known Young's modulus on the vaginal probe [42]. Even though the potential advantage of calculating the exact elasticity coefficient of the cervix method should be better standardized as the authors report a good intra-observer intra-class correlation, but a quite poor inter-observer intra-class correlation [20].…”
Section: The Type Of Elastographic Methods Usedmentioning
confidence: 99%
“…Interesting is the approach proposed by the Danish group, which proposed to overcome the problem of the exerted force by positioning a reference cup with known Young's modulus on the vaginal probe [42]. Even though the potential advantage of calculating the exact elasticity coefficient of the cervix method should be better standardized as the authors report a good intra-observer intra-class correlation, but a quite poor inter-observer intra-class correlation [20].…”
Section: The Type Of Elastographic Methods Usedmentioning
confidence: 99%
“…Molina et al noted no statistically significant differences between cervices except in the precise area that received the force from the transducer. Various approaches are currently being employed to address this problem of transducer force standardization (Fruscalzo et al, 2015; Hee et al, 2013; Hernandez-Andrade et al, 2014). …”
Section: Cervical Tissue Mechanical Propertiesmentioning
confidence: 99%
“…The technique with the probe reference ‘cap’ has shown promise before in clinic applications (for example, Hee et al 2013 and 2014). The present study used a similar technique to measure the modulus of the perineal body, an important anatomical structure that is widely discussed in the gynecology and obstetrics literature but rarely studied.…”
Section: Discussionmentioning
confidence: 99%