Quantitative gas composition analysis method for a wide pressure range up to atmospheric pressure—CO2 plasma case study

Abstract: A mass spectrometer with a custom sampling system comprising one fixed and one variable orifice is presented. The custom sampling system allows the determination of the gas composition in the pressure range from 5 mbar to 1000 mbar, with low gas-demixing (<1.5%). A case study of mass spectrometer optimization and calibration for the measurement of relative concentration of CO2, CO, O2, and N2 gases is presented, together with an example of the CO2 conversion at a microwave plasma torch. The absolute error o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
18
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 17 publications
(23 citation statements)
references
References 50 publications
1
18
0
1
Order By: Relevance
“…D'Isa reported a maximal efficiency of around 25 % for the quasi‐atmospheric pressure measurements but a maximal conversion of about 15 % 20, 22. Hecimovic et al reported that the CO 2 conversion efficiency at a pressure of 200 mbar is independent of the measurement position along the exhaust gas tube and independent of the position of the heat exchanger 20. They noticed no decrease in the conversion and concluded that in their case, the quenching took place only in the first 4 cm above the resonator top (which, correspond to a downstream distance of z = 9 cm in this work).…”
Section: Resultsmentioning
confidence: 97%
See 3 more Smart Citations
“…D'Isa reported a maximal efficiency of around 25 % for the quasi‐atmospheric pressure measurements but a maximal conversion of about 15 % 20, 22. Hecimovic et al reported that the CO 2 conversion efficiency at a pressure of 200 mbar is independent of the measurement position along the exhaust gas tube and independent of the position of the heat exchanger 20. They noticed no decrease in the conversion and concluded that in their case, the quenching took place only in the first 4 cm above the resonator top (which, correspond to a downstream distance of z = 9 cm in this work).…”
Section: Resultsmentioning
confidence: 97%
“…The main differences are the absence of a tubular reactor for the incorporation of membranes for gas separation, a lower position of the heat exchanger and the presence at quasi atmospheric pressure of a pump to suck away the effluent gas. D'Isa reported a maximal efficiency of around 25 % for the quasi‐atmospheric pressure measurements but a maximal conversion of about 15 % 20, 22. Hecimovic et al reported that the CO 2 conversion efficiency at a pressure of 200 mbar is independent of the measurement position along the exhaust gas tube and independent of the position of the heat exchanger 20.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Zum Verständnis zur Selektion des Plasmaprozesses und dessen Charakterisierung ist die Plasmadiagnostik essenziell und wird hier ebenfalls kurz angerissen. 34) Aus der entsprechenden Teilchendichte lassen sich die Konversion und -mit Hinzunahme des Gasflusses und der zugeführten Leistung zum Plasma -die Energieeffizienz quantifizieren. Für eine zuverlässige Bestimmung der Effizienz muss die Temperatur des entnommenen Gases allerdings nahe Raumtemperatur sein.…”
Section: Basischemikalien Durch Plasmaprozesse Herstellenunclassified