2013
DOI: 10.1080/10826076.2012.734002
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative Determination of Milnacipran HCL in Rabbit Plasma by HPLC and Its Application to Pharmacokinetics Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 15 publications
0
7
0
Order By: Relevance
“…The validation of an analytical method authenticates the parameters of the method for application (Parejiya et al, 2014). The method used for the determination of venlafaxine HCl was validated for precision, accuracy, linearity, sensitivity and robustness.…”
Section: Methods Validationmentioning
confidence: 89%
See 1 more Smart Citation
“…The validation of an analytical method authenticates the parameters of the method for application (Parejiya et al, 2014). The method used for the determination of venlafaxine HCl was validated for precision, accuracy, linearity, sensitivity and robustness.…”
Section: Methods Validationmentioning
confidence: 89%
“…The linearity was evaluated by linear regression analysis. Quantitative analytical results are greatly affected by the quality of the calibration curve (Parejiya et al, 2014). The calibration curve was obtained with seven concentrations of reference standard venlafaxine HCl solution (10, 50, 100, 200, 300, 400 and 500 μg mL −1 ) of the target analyte concentrations for the chromatographic method.…”
Section: Linearitymentioning
confidence: 99%
“…4 It acts by unique and equal inhibition of noradrenaline and serotonin neurotransmitters reuptake. 5 In the previous analytical literature, MLC was assayed by various techniques which include GC-MS, 6 liquid chromatography with uorescence or UV detection, 7,8 spectrouorimetry by derivatization with ninhydrin 9 or NBD-Cl, 10 UVspectrophotometric detection at 223 nm 11,12 and colorimetry using ninhydrin 13 or ion pair complex. 14 The approach target was simple development for accurate assay of MLC in the spiked biological uid, and tablets.…”
Section: Introductionmentioning
confidence: 99%
“…[ 6 ] However, the developed method still suffered from low sensitivity (LOQ = 1.67 μg ml −1 ) and tedious procedures as it required heating at high temperature to 120°C using a glycerol bath. Spectrofluorimetric, [ 7–9 ] chromatographic [ 10–19 ] and capillary electrophoretic methods [ 20 ] were reported for assay of MCP. The reported spectrofluorimetric methods [ 7,8 ] used an expensive fluorogenic reagent that has a high fluorescence background and required acidification with high concentrations of hydrochloric acid to decrease reagent interference.…”
Section: Introductionmentioning
confidence: 99%