2011
DOI: 10.1016/j.jchromb.2011.07.006
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative determination of juvenile hormone III and 20-hydroxyecdysone in queen larvae and drone pupae of Apis mellifera by ultrasonic-assisted extraction and liquid chromatography with electrospray ionization tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
34
1

Year Published

2012
2012
2017
2017

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 49 publications
(35 citation statements)
references
References 26 publications
0
34
1
Order By: Relevance
“…Further activation of m/z = 235 and 249 generates m/z = 217 [M+H-CH 3 OH-H 2 O] + and m/z = 207 [M+H-CH 3 OH-CO] + , corresponding to the combined loss of one methanol group and water, and to the loss of a CO group, respectively. In contrast to previous reports(25), our data support the generation of m/z = 217 as a product of 267->235->217 and 267->249->217. The activation of m/z = 217 produces m/z = 189 [M+H-CH 3 OH-H 2 O-CO] + , which further fragments into m/z = 147 [M+H-CH 3 OH-H 2 O-CO-CH 3 CH=CH 2 ] + .…”
Section: Resultscontrasting
confidence: 99%
See 3 more Smart Citations
“…Further activation of m/z = 235 and 249 generates m/z = 217 [M+H-CH 3 OH-H 2 O] + and m/z = 207 [M+H-CH 3 OH-CO] + , corresponding to the combined loss of one methanol group and water, and to the loss of a CO group, respectively. In contrast to previous reports(25), our data support the generation of m/z = 217 as a product of 267->235->217 and 267->249->217. The activation of m/z = 217 produces m/z = 189 [M+H-CH 3 OH-H 2 O-CO] + , which further fragments into m/z = 147 [M+H-CH 3 OH-H 2 O-CO-CH 3 CH=CH 2 ] + .…”
Section: Resultscontrasting
confidence: 99%
“…That is, the most abundant fragmentation transitions utilized were 267->235 (primary) and 267-> 147 (secondary). Previous reports have also utilized 267-> 235 as a primary and 267-> 217 as secondary MRM transitions for LC-MS/MS analysis(25, 27). …”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The liquid chromatography mass spectrometry ecdysone analyses were performed with the liquid chromatography instrument UHPLC Agilent Technologies 1290 Infinity (Santa Clara, California, USA) in combination with an Agilent triple quadruple 6430 mass spectrometer with electrospray ionization (Santa Clara, California, USA) (adapted from [31,32]). The system operation was controlled and processed with the software MassHunter B06.00.…”
Section: Methodsmentioning
confidence: 99%