2006 IEEE Nuclear Science Symposium Conference Record 2006
DOI: 10.1109/nssmic.2006.353702
|View full text |Cite
|
Sign up to set email alerts
|

Quantifying the Effects of Acquisition Parameters in Cardiac SPECT Imaging and Comparison with Visual Observers

Abstract: Abstract-Significant debate remains whether the established imaging protocols for myocardial perfusion SPECT delivers optimal image quality. This debate has been intensified with the introduction of advanced iterative reconstruction techniques which differ considerably from the FBP reconstruction technology commonly available when the current protocols were established. In order to characterize and classify image quality affecting factors, simulations combined with time consuming observer studies are often use… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2006
2006
2012
2012

Publication Types

Select...
3
1

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 10 publications
0
3
0
Order By: Relevance
“…Gated timeslots, matrix size, and ejection fraction were varied according to Table II. From this measured data ("reference"), we created "whatif" datasets. For this we developed a DICOM compatible tool that extracts angular views from a projection data set, rebins the matrix and pixel size and reduces counts in a pixel by a selected fraction using binomial subsampling while maintaining the Poisson character of the data [5]. In this way, we create gated projection data sets with different levels of counts and angular sampling for the assessment of clinical and rapid protocols.…”
Section: A Data Acquisition and Processingmentioning
confidence: 99%
“…Gated timeslots, matrix size, and ejection fraction were varied according to Table II. From this measured data ("reference"), we created "whatif" datasets. For this we developed a DICOM compatible tool that extracts angular views from a projection data set, rebins the matrix and pixel size and reduces counts in a pixel by a selected fraction using binomial subsampling while maintaining the Poisson character of the data [5]. In this way, we create gated projection data sets with different levels of counts and angular sampling for the assessment of clinical and rapid protocols.…”
Section: A Data Acquisition and Processingmentioning
confidence: 99%
“…From this measured data ("reference"), we create "what-if" datasets. For this we developed a DICOM compatible tool which extracts angular views from a projection data set, rebins the matrix and pixel size and reduces counts in a pixel to some fraction f using binomial subsampling, and maintaining the Poisson character of the data [15]. On purpose we don't allow for projection view interpolation as such data would not correspond to data acquired with our systems.…”
Section: A Overviewmentioning
confidence: 99%
“…Various studies have shown improvements in image quality and lesion detectability by optimizing the number of EI and choosing an appropriate reconstruction method by doing phantom measurements, as well as human observer studies (11)(12)(13)(14). However, the optimal number of EI and reconstruction method is dependent on the specific situation and needs to be optimized for the specific clinical task.…”
mentioning
confidence: 99%