Quantifying the effect of seed orientation in postplanning dosimetry of low‐dose‐rate prostate brachytherapy

Abstract: Based on the results from this study, seed orientations have no significant impact of CTV and urethra dose metrics but can affect OARs that are external to the CTV.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
15
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 18 publications
(19 citation statements)
references
References 47 publications
4
15
0
Order By: Relevance
“…This effect has been shown to cause < 2% differences in D 90 for LDR prostate implants with conventional seeds. 83,84 However, the magnitude and spatial extent of these dose calculation errors are larger for this source model (i.e., L = 1.00 cm) than for sources having L ≤ 0.4 cm. Consequently, no CON / an (r) are recommended for this source model.…”
Section: A73 Model Cs10 Anisotropy Functionsmentioning
confidence: 91%
“…This effect has been shown to cause < 2% differences in D 90 for LDR prostate implants with conventional seeds. 83,84 However, the magnitude and spatial extent of these dose calculation errors are larger for this source model (i.e., L = 1.00 cm) than for sources having L ≤ 0.4 cm. Consequently, no CON / an (r) are recommended for this source model.…”
Section: A73 Model Cs10 Anisotropy Functionsmentioning
confidence: 91%
“…It is possible that a single false positive or false negative detection may not have significant effects on the dose–volume calculations, because of the low dose of an individual seed. Finally, the information on seed orientation gained through MR‐only seed localization may improve the accuracy of the dose calculations by allowing the use of anisotropic dose distributions …”
Section: Discussionmentioning
confidence: 99%
“…First, the SPOT PROÔ system that was employed to calculate the final dose statistics for both IPSA and SGA used the 1D formalism; therefore, the same was used for the SGA code for consistency sake. Second, a recent study performed by Fekete et al (30) has shown that the seed orientation does not affect main clinical dosimetric quantities of interest in a statistically significant way for the clinical target volume and urethra. For the target structure, dosimetric constraints were represented by two sets of dose points, surface and volume.…”
Section: Formulation Of Objective Functionmentioning