2023
DOI: 10.1002/cbdv.202201186
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of Phenolic Component by LC‐HESI‐MS/MS and Evaluation of Antioxidant Activities of Crocus Ancyrensis (Ankara Çiğdemi) Extracts Obtained with Different Solvents

Abstract: In this study, Crocus ancyrensis was extracted from different parts of the plants with various solvents and their antioxidant activities and phenolic contents were investigated in detail for the first time. The highest amount of total phenolic substance in all parts of the plant was determined in the stigmaless flower. In the DPPH and FRAP methods, the highest antioxidant activity was obtained from the water extraction from the plant. Rutin is the highest detected by LC MS/MS. Stigmaless flower extract in all … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 24 publications
0
5
0
Order By: Relevance
“…ODS Hypersil 4.6 * 250 mm column was used. The MS/MS analysis conditions are as follows: capillary temperature: 300 °C, vaporizer temperature: 350 °C, sheat gas pressure: 30 Arb, Aux gas pressure: 13 Arb, positive polarity: 2500 V, negative polarity: 2500 V, discharge current: 4 µA 14 , 15 . Quantification was evaluated according to MS/MS.…”
Section: Methodsmentioning
confidence: 99%
“…ODS Hypersil 4.6 * 250 mm column was used. The MS/MS analysis conditions are as follows: capillary temperature: 300 °C, vaporizer temperature: 350 °C, sheat gas pressure: 30 Arb, Aux gas pressure: 13 Arb, positive polarity: 2500 V, negative polarity: 2500 V, discharge current: 4 µA 14 , 15 . Quantification was evaluated according to MS/MS.…”
Section: Methodsmentioning
confidence: 99%
“…The column oven was set to 30 °C, the solvent flow rate was 0.7 mL/min and the analysis lasted for 34 min. The following are the criteria for the MS/MS analysis: Temperatures of the capillary are 300 °C, the vaporizer is 350 °C, the sheat gas pressure is 30 Arb, the aux gas pressure is 13 Arb, the positive and negative polarities are 2500 V and 4 µA, respectively 31 , 32 .…”
Section: Methodsmentioning
confidence: 99%
“…The mobile phase employed for this study was selected after a combination of several trials to determine the optimal ionization and separation of the molecules. The compounds listed in Table 1 were analyzed using LC MS/MS ( Kayir et al, 2023 ).…”
Section: Methodsmentioning
confidence: 99%