2015
DOI: 10.1039/c4ew00033a
|View full text |Cite|
|
Sign up to set email alerts
|

Quantification of corrosion inhibitors used in the water industry for steam condensate treatment: the indirect electroanalytical sensing of morpholine and cyclohexylamine

Abstract: Corrosion inhibitors are widely used in the water industry for steam condensate treatment.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 23 publications
0
4
0
Order By: Relevance
“…On the other hand, the effluent from the TOC meter and O 3 injector was more acidic. While a pH higher than 8.5 can favor fouling and deposits in these systems, an acidic pH (less than 3.0) increases the risk of corrosion (Kolliopoulos et al, 2015). An important result was the low total alkalinity at P1 that had the highest pH value; this shows that effluent from P1 can be easily neutralized before reuse.…”
Section: Parametersmentioning
confidence: 82%
“…On the other hand, the effluent from the TOC meter and O 3 injector was more acidic. While a pH higher than 8.5 can favor fouling and deposits in these systems, an acidic pH (less than 3.0) increases the risk of corrosion (Kolliopoulos et al, 2015). An important result was the low total alkalinity at P1 that had the highest pH value; this shows that effluent from P1 can be easily neutralized before reuse.…”
Section: Parametersmentioning
confidence: 82%
“…In this approach, chemical moieties are employed which first chemically react with the target analytes, in this case MPA and 2-AI, to produce a product which can be electrochemically monitored and provide the indirect electrochemical signal with which to measure the target analytes. Based on previous work for the indirect detection of amine cyclohexylamine 27 the following mediator was chosen: N,N′-(1,4-phenylene) dibenzenesulfonamide.…”
Section: Electrochemical Detection Of Mpa and 2-aimentioning
confidence: 99%
“…a pH above the pK a ) and not as their conjugative acids as in this form they do not react with the selected mediators. 27 Fig. 2A depicts typical linear sweep voltammograms observed using the indirect sensing approach where the product is monitored using SPEs.…”
Section: Electrochemical Detection Of Mpa and 2-aimentioning
confidence: 99%
“…There is a strong need for analytical methods for on-site analysis and quantification of corrosion inhibitor residues in the large HP water tube boiler plants systems with fast response times, preferably with little or no special sample preparation. From such samples, the analytical data obtained should be useful in maintaining the appropriate levels of the inhibitor in the water tube boiler plants. This is useful not only for quality control but in the development of new effective corrosion inhibitors to combat corrosion in large high pressure (HP) water tube boiler plants. …”
mentioning
confidence: 99%