1998
DOI: 10.1002/(sici)1098-1101(1998)13:2<47::aid-jca1>3.0.co;2-8
|View full text |Cite
|
Sign up to set email alerts
|

Quality evaluation of plateletpheresis using the new AMICUS (Baxter) cell separator: Evolution of CD 62 expression

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
6
0

Year Published

1999
1999
2011
2011

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 25 publications
1
6
0
Order By: Relevance
“…Although not statistically significant, the CD62P expression increased to some extent during storage. Other studies have shown that the percentage of activated (CD62P expressing) platelets increases during storage (Rinder et al, 1993;Holme et al, 1997;Laurencet et al, 1998). Similarly, the changes in morphology and aggregation are similar to those reported during platelet storage in other systems (Glaser et al, 2001).…”
Section: Discussionsupporting
confidence: 77%
“…Although not statistically significant, the CD62P expression increased to some extent during storage. Other studies have shown that the percentage of activated (CD62P expressing) platelets increases during storage (Rinder et al, 1993;Holme et al, 1997;Laurencet et al, 1998). Similarly, the changes in morphology and aggregation are similar to those reported during platelet storage in other systems (Glaser et al, 2001).…”
Section: Discussionsupporting
confidence: 77%
“…All parameters were assayed on the morning of Days 1, 5, and 7 of storage. All metabolic, key storage, and functional parameters were in the range of PLT storage variables published previously 6,18 ‐20 . PLT metabolic parameters were not affected by differences in rest period during storage.…”
Section: Discussionmentioning
confidence: 55%
“…It has been previously demonstrated that different cell separators induce different degrees of PLT activation, depending on their collection modalities. [7][8][9]21,[23][24][25] Plateletpheresis, obtained using the surge technology, like those obtained with the Haemonetics MCS device, show lower levels of P-selectin when compared to those obtained using Cobe Spectra or CS-3000 machines. 21 These observations are in keeping with our findings, based on the particular collection modality of the plasma-reduced PLT collection program, where a prolonged contact between high-concentration PLTs and the plastic surface takes place within the collection set.…”
Section: Discussionmentioning
confidence: 96%
“…It has been previously demonstrated that different cell separators induce different degrees of PLT activation, depending on their collection modalities 7‐9 , 21,23‐25 . Plateletpheresis, obtained using the surge technology, like those obtained with the Haemonetics MCS device, show lower levels of P‐selectin when compared to those obtained using Cobe Spectra or CS‐3000 machines 21 .…”
Section: Discussionmentioning
confidence: 99%